The LD33, LD34, LD36 and LD37 are supplied with 4.5 litre pots.  
The LD38, LD39 and LD43 models accommodate a mix of gastronorm containers and bridging bars are 
provided as  standard. Containers are supplied.                     
The LD39 and LD43 models are designed to hold 1/4 and 1/2 size gastronorm trays. 
The LD38 is supplied with 3 x 1/4 gastronorm trays and lids. 
Wet bains marie require a water level of approx. 38mm to be maintained during operation. This will allow 
pot bases to be immersed. A drain valve with safety catch is located on unit front for well draining. Never 
drain well until water cools.  
 
Using a Bains Marie 
 
A bains marie is used to store hot food prior to and during serving whilst maintaining the proper         
temperature. Successful achievement of this is dependent upon a number of factors, such as type of food, 
container amount and skill and experience of the operator. The following hints may be found useful in 
achieving satisfactory results. 
Containers should be warm before being loaded with hot food. Place complete with lids, in the chosen 
position(s). Switch on at Full (6) setting until the desired temperature is reached. Load food quickly and 
replace cover(s) before setting control as required. 
When serving, it is advantageous to raise the setting to counteract heat loss incurred by lid removal. Take 
care not to overheat food and replace lids when it is practicable to do so. 
 
Cleaning a Bains Marie 
 
Clean containers as soon as possible after use with hot water and detergent. Soap filled pads may be used 
to remove stubborn deposits. Avoid leaving empty used containers in the unit. Food deposits may bake on. 
 
SECTION 4 – SERVICING 
 
LD33, LD36, LD38 and LD39 DRY BAINS MARIE 
LD34, LD37 and LD43 WET BAINS MARIE 
 
SERVICE ACCESS 
 
Base Plate 
Upturn unit and rest it at edge of a work surface with rear upstand overhanging edge. 
Undo base plate fixings to remove base plate. 
 
FUNCTIONAL COMPONENTS 
 
Temperature Control. 
Remove access panel. 
Remove control knob. 
Remove electrical connections, noting their positions. 
Carefully remove phial from retaining clips and clear  structure. 
Undo fixings that secures control to panel and remove. 
Replace in reverse order. 