Technical Installation & Information Table
Model
Width
Depth
Height
Weight Rating
Fuse Rating
LD33 Dry Bains Marie
300mm
630mm
285mm
15kg
0.48kW
3 amp
LD34 Wet Bains Marie
300mm
630mm
285mm
15kg
1.0kW
5 amp
LD36 Dry Bains Marie
450mm
630mm
285mm
18kg
0.75kW
5 amp
LD37 Wet Bains Marie
450mm
630mm
285mm
18kg
1.0kW
5 amp
LD38 Dry Bains Marie
300mm
630mm
285mm
15kg
0.48kW
3 amp
LD39 Dry Bains Marie
600mm
630mm
285mm
22kg
0.75kW
5 amp
LD43 Wet Bains Marie
600mm
630mm
285mm
22kg
2.0kW
13 amp
SECTION 1 – SITING
All PRO-LITE models have been designed in a modular form which consists of base, counter and free-
standing units.
Information which relates to individual models is listed in Table 1.
Free-standing and base models should be installed upon a firm, level surface and adjustable feet are
provided for levelling purposes.
Counter units must be positioned upon a table, counter or similar surface.
Vertical and horizontal clearances required from the top and sides of a particular unit to any overlying
combustible surface (ie wall, partition, etc) are listed in Table 1. Relevant fire regulations must be complied
with.
Mounting Counter Units on the Oven
When mounting a counter unit upon a PRO-LITE oven, it is recommended that units which carry liquids, i.e.
fryers and bain marie, are secured as follows:
Remove oven outer back panel.
Remove oven crown plate.
Position unit(s) which require to be secured upon oven.
Secure hob unit(s) to oven through side flange centre holes into the threaded inserts in the base(s) of hob
unit(s). Use fixings provided (packed separately) and replace oven back panel.
The unit is now ready for electrical connection.
Mounting Counter Units upon a Hotcupboard
PRO-LITE hotcupboards are designed to be used in conjunction with counter models. Assembly is
achieved by means of two shouldered fixings being applied to the underside of a top unit from inside a base
appliance as detailed in Figure 1.
Figure 1 Front view
SECTION 2 - ELECTRICAL SUPPLY AND CONNECTION
Electrical ratings are as stated on the unit data plate. The listing in Table 1 is based on standard UK
specification at 230V.
Wiring must be executed in accordance with the regulations listed in this booklet.
WARNING: Each individual appliance must be earthed!