2
ArtNo.132-0001 - 1 phase 240Vac 50Hz
1-phase 230 V
AC
50 Hz
Electrical Connection Safety
n
WARNING:
THE APPLIANCE MUST BE
EARTHED.
The cooker is preset for a single-phase earthed
electrical connection. It is essential to install
a multi-pole circuit breaker that completely
disconnects the appliance from the mains, with
a minimum contact break distance of 3 mm.
The total electrical load of the appliance is
approximately 15 kW. The cable size used
should be suitable for this load and comply
with all local requirements (i.e. PVC Insulated
cable IEC 60227 – code 53 for ordinary cables).
Access to the mains terminal is gained by
removing the electrical terminal cover box on
the back panel. Connect the mains cable to the
correct terminals for your electrical supply type
(
Fig. 1.1
and
Fig. 1.2
). Check that the links are
correctly fitted and that the terminal screws are
tight. Secure the mains cable using the cable
clamp.
Minimum temperature rating T105.
Read the instructions before installing or using
this appliance.
•
This appliance is heavy so take care when
moving it.
•
The cable size and type should be suitable
for the Electrical Load of the appliance and
comply with the relevant national and local
requirements.
•
The cooker may be installed in a kitchen/
kitchen diner but
NOT
in a room
containing a bath or shower.
•
The cooker
MUST NOT
be connected to an
ordinary domestic power point.
•
It is normal for the hob control display
to flash for about 2 seconds during first
power setting.
•
Set the clock to make sure that the oven is
functional – see the relevant section in this
manual.
Fig. 1.1
Fig. 1.2
Summary of Contents for Nexus 90 Induction
Page 1: ...USER GUIDE INSTALLATION INSTRUCTIONS Nexus 90 Induction Australia U111049 06d...
Page 2: ......
Page 4: ...ii...
Page 49: ...45 NOTE...
Page 50: ...46 NOTE...
Page 51: ...47 NOTE...
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ...Clarence Street Royal Leamington Spa Warwickshire CV31 2AD England www falconworld com...