33
04
Cooking Zone
Temperature Too
High Or Remains
Constant During
Cooking.
Reset Appliance
Switch Appliance OFF for 10
Seconds then On.
Pan empty / Too Hot
Test Disc may be overheated
–
allow for cooling.
Cooking Zone Self Protected due
to Abnormal Heat Build up
Allow Cook Zone to cool for
couple of Minutes
Temperature sensor faulty
(Constantly records a Ambient
Temperature)
Check all electrical
connections to the inductor coil
Replace defective Coil
05
Controls Failure
Reset Appliance
Switch Appliance OFF for 10
Seconds then On.
Controls faulty or incorrectly
Wired
Check all electrical
connections to the controls &
Generator
Replace defective Controls
Assembly
06
Generators Internal
Temperature Too
High.
Reset Appliance
Switch Appliance OFF for 10
Seconds then On.
See Fault 3
See Fault 3
07
Cooking Zone
Temperature Sensor
Reset Appliance
Switch Appliance OFF for 10
Seconds then On.
Temperature sensor faulty /
Malfunctioned
Check all electrical
connections to the inductor coil
Replace defective Coil
08
Mains Supply Failure
Reset Appliance
Switch Appliance OFF for 10
Seconds then On.
Fault in mains supply
Is there a Phase(s) Down
Has supply been interrupted
intermittently?
Has MCB Tripped?
Has Supply Under / Over
Voltage?
09
N/A
N/A
N/A
10
Communication Error
Reset Appliance
Switch Appliance OFF for 10
Seconds then On.
Failure on LIN or CAN-Bus
Check all communications
connections
Summary of Contents for i91104C
Page 23: ...23 7 3 ACCESSING THE GENERATOR AND ELECTRICS 7 3 1 Remove filter 7 3 2 Remove front panel...
Page 35: ...35 9 0 CIRCUIT DIAGRAM i91104 5 Circuit Diagram...
Page 36: ...36 i91104 5C Circuit Diagram...
Page 37: ...37 10 0 WIRING DIAGRAM i91104 5 Wiring diagram...
Page 38: ...38 i91104 5 Wiring diagram...
Page 39: ...39 i91104 5 i91104 5C Coil Wiring Diagram...
Page 40: ...40 i91104 5C Wire Diagram...
Page 41: ...41 i91104 5C Wire Diagram...