background image

12 - 15mm

ConnectingLink

and springclip

Linkage rod

Locknut

Turnbuckle

Link pin

Sprocket

Spiral pin

68mm approx.

3.23 DOOR WINDOW (G7204 and 7208 ONLY)
a) Remove door as described in Section 3.21.
b) Remove all fixings on top and bottom flanges of

door plus those which secure sealingstrip down

side flange.

c) Lay door down on outer surface and prise inner

liningout. The door window assembly may now be

removed.

d) When replacing only one single glass panel,

dismantle frame by removingall fixings around

periphery of window assembly.

e) Replace glass and sealing strip if necessary.

Carefully re-assemble window structure.

f) Re-fit all the door components in reverse order.

3.24 DOOR LINKAGE SPROCKET
a) Remove door as Section 3.2.1.
b) Slacken turnbuckles to allow chain to be slipped off

sprocket.

c) Push out roll pin which holds sprocket to lower

hinge pin. Remove pin securing door switch cam if

right sprocket is being replaced.

d) Pull up lower hinge pin and remove sprocket.
e) Replace in reverse order. Refer to door linkage

adjustment section for alignment and tensioning of

components.

Figure 2

Figure 3

3.25 DOOR LINKAGE CHAIN and ROD
a) Remove bottom front panel as Section 3.2.1.
b) Slacken turnbuckle to remove tension from chains.
c) Remove springclip from link which joins chain to

turnbuckle. Push out link and withdraw chain and

rod assembly.

d) Replace in reverse order. Refer to door linkage

adjustment section, door linkage alignment

sections and Figures 2 and 3.

3.26 DOOR LINKAGE ADJUSTMENT

and TENSIONING

Due to operational stretchingof components or

removal for maintenance, occasions will arise when

doors linkage mechanism will require adjustment.
The method to use is as follows:
Push door handle until RH door makes contact with

seal. LH door should now be 12 to 15mm proud of

RH door at vertical join - see Figure 2. If LH door

distance is less than this dimension, slacken both

turnbuckle locknuts and rotate left turnbuckle to

reduce length on rod and right turnbuckle to increase

length on rod by same amount.
Repeat procedure until desired dimension is

achieved.
If left door distance is greater than desired setting

then the above procedure should be carried out in

reverse.
After doors are synchronised, the linkage should be

put under tension by slightly twisting the turnbuckles

toward one other by the same small amount.

The tension should be such that no free play is

available between chains and sprockets.

3.27 DOOR LINKAGE ALIGNMENT
When linkage components have been disturbed

duringrepair, the initial coarse alig

nment of the

assembly will be achieved by positioningthe chains

on their sprockets as indicated in Figure 3. The doors

should be in the closed position whilst carryingout

this operation.

All manuals and user guides at all-guides.com

Summary of Contents for G7204

Page 1: ...he Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTA...

Page 2: ...l supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a...

Page 3: ...iances should be added together In stallation should be made in accordance with local and or national regulations applicable at the time A competent installer MUST be employed 1 4 GAS SUPPLY The incom...

Page 4: ...remove gas pressure governor b Manoeuvre unit into required location Level by turning adjustable feet as required Fasten locknuts on feet 2 2 CONNECTION TO GAS SUPPLY Fit gas pressure governor suppli...

Page 5: ...setting check COOK and HOLD timer works and that at end of pre set time interval selected control switches from cook to hold thermostat j With oven in HOLD mode i e hold timer at 0 and mode switch at...

Page 6: ...d replace as necessary 3 5 IGNITION ELECTRODES a Remove appropriate burner as Section 3 3 b Disconnect conductor from electrode c Remove screw which secures electrode to bracket Withdraw electrode d R...

Page 7: ...d timer are remade but not pinched 3 14 BUZZER a Drop down control panel as Section 3 2 2 b Undo nut securing buzzer to bracket c Withdraw push on terminals from both in line connectors d Replace in r...

Page 8: ...ixing nut on capacitor base and remove unit d Replace in reverse order Figure 1 3 20 OVEN DOOR SEAL REPLACEMENT Seal is fitted to front frame using countersunk screws When fitting new seal place metal...

Page 9: ...turnbuckle Push out link and withdraw chain and rod assembly d Replace in reverse order Refer to door linkage adjustment section door linkage alignment sections and Figures 2 and 3 3 26 DOOR LINKAGE A...

Page 10: ...W I R I N G D I A G R A M B W 3 9 0 1 9 All manuals and user guides at all guides com...

Page 11: ...All manuals and user guides at all guides com...

Page 12: ...All manuals and user guides at all guides com...

Reviews: