3.6 GAS TAPS
To Service
Remove the fixings from front of tap body and
withdraw spindle and niting arrangement thus
allowing plug to be eased out.
Clean plug and body with a soft rag and re-grease
with an approved high temperature lubricant. Apply
grease sparingly and do not block gas passageways
of plug and body.
When re-assembling parts, insert plug into body with
gas passageways of plug and body.
Secure end cap to body, noting that fixing holes line
up in one way only.
Note
Plugs and bodies are machined in pairs and are
therefore not interchangeable. Always clean one tap
at a time.
To Remove
Undo brass nut at compression fitting on gas supply
pipe at rear of gas tap.
Remove thermocouple connection from FFD section
of tap.
Undo fixings and gently remove tap from supply
manifold.
3.7 GOVERNOR
This applies to NATURAL GAS appliances only.
The type of governor used is maintenance free.
Check blue dust cap covering vent is fitted and in
good condition. This protects breather hole.