background image

3.6 GAS TAPS
To Service
Remove the fixings from front of tap body and

withdraw spindle and niting arrangement thus

allowing plug to be eased out.
Clean plug and body with a soft rag and re-grease

with an approved high temperature lubricant. Apply

grease sparingly and do not block gas passageways

of plug and body.
When re-assembling parts, insert plug into body with

gas passageways of plug and body.
Secure end cap to body, noting that fixing holes line

up in one way only.
Note
Plugs and bodies are machined in pairs and are

therefore not interchangeable. Always clean one tap

at a time.
To Remove
Undo brass nut at compression fitting on gas supply

pipe at rear of gas tap.
Remove thermocouple connection from FFD section

of tap.
Undo fixings and gently remove tap from supply

manifold.

3.7 GOVERNOR
This applies to NATURAL GAS appliances only.
The type of governor used is maintenance free.
Check blue dust cap covering vent is fitted and in

good condition. This protects breather hole.

SECTION 4 - SPARES

When ordering spare parts, always quote the

appliance type and serial number. This information

will be found on the data plate, located on a plate

behind the rear flue upstand. A list of items available,

along with code numbers is enclosed with the

document pack.