background image

2.6INSTRUCTION TO USER
After installing and commissioning appliance, hand

User Instructions to user or purchaser and ensure

that the person(s) responsible understands the

instructions for lighting, cleaning and correct use of

the appliance. Particular emphasis should be given to

safe operation of the drain valve. It is important to

ensure that location of gas isolating cock is made

known to user and that procedure for operation in

event of an emergency be demonstrated.

SECTION 3 - SERVICING

and CONVERSION

Important
Before attempting any servicing, turn off isolating

cock and take steps to ensure that it is not

inadvertently turned on.
AFTER ANY MAINTENANCE TASK, CHECK THE

APPLIANCE TO ENSURE THAT IT PERFORMS

CORRECTLY AND CARRY OUT ANY NECESSARY

ADJUSTMENTS AS DETAILED IN SECTION 1.
After carrying out any servicing or exchange of gas

carrying components -
ALWAYS CHECK FOR GAS SOUNDNESS!

3.1 CONVERSION PROCEDURE CHECK LIST
To convert from NATURAL to PROPANE GAS
Change injectors
Remove governor and adjust for new inlet pressure
Change data plate
To convert from PROPANE to NATURAL GAS
Change injectors
Install governor and adjust inlet pressure accordingly
For detailed procedures, refer to appropriate sections

of this document
Change data plate

3.2 ACCESS TO GAS CIRCUIT COMPONENTS
Access can be gained by opening door at front of

appliance. On G350/12 model (double pan), the

circuit components associated with a particular pan

are mounted on same side of support box as pan

itself.

3.3 BURNERS
Burners should be cleaned periodically to maintain

maximum performance.
3.3.1 Main Burner
To Remove
a) Remove burner pipe by unscrewing compression

fittings at each end.

b) From underneath the burner, remove fixings that

secure pilot bracket to burner. Ease pilot burner

assembly clear of burner by moving it slightly

downward.

c) Remove four screws securing burner support

straps to fryer body. Thus allowing burner to be

manipulated clear.

d) Replace in reverse order. Check all connections

for gas soundness.

3.3.2 Pilot Burner Assembly
To Remove
a) Remove thermocouple and pilot supply pipe from

pilot assembly, take care not to lose injector that

will be removed with union nut.

b) Disconnect spark ignitor lead at pilot.

c) Remove two hex nuts securing pilot bracket to

lower side of burner and remove pilot burner

complete with bracket.

Replace in reverse order, ensuring that pilot injector

is correctly located in annular groove in compression

nut. Check all connections for gas soundness.
3.4 INJECTORS
3.4.1 Main Injector
To Remove
The injector can be removed without the necessity for

removing the burner.

a) Using a 16mm open ended spanner, reach inside

burner air entry and engage spanner on hex body

of injector.

b) Slacken injector, reach inside and completely

unscrew by hand.

If injector needs cleaning, soak it in a suitable solvent.

Do not use metal objects to clear it.

3.5 FLAME FAILURE THERMOCOUPLE
To remove thermocouple from pilot assembly, undo

split nut and withdraw.
To disconnect overheat limit device from circuit, pull

off spade connections at interrupter.
To disconnect thermocouple from valve, undo hex nut

at valve body.

3.6PIEZO IGNITER/SPARK ELECTRODE
3.6.1 Piezo Igniter
To remove piezo unit, pull off lead at rear then

remove fixing nut at rear of unit.
3.6.2 Spark Electrode
This is an integral part of pilot burner assembly.
To Replace
a) Remove thermocouple.
b) Remove nut securing lead.
c) Undo gland nut fixing electrode to pilot burner

body.

d) Remove electrode by withdrawing downward.

All manuals and user guides at all-guides.com

Summary of Contents for G350/12

Page 1: ...ing Further to this the users instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance Particular emphasis should be made with regard to...

Page 2: ...l supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a...

Page 3: ...uld be added Installation should be made in accordance with local and or national regulations applying at the time and a competent installer must be employed 1 4 GAS SUPPLY The incoming service must b...

Page 4: ...ll of pan Purge air from system and light burner using the following procedure Warning If pilot is extinguished either intentionally or unintentionally wait at least 3 minutes before re lighting gas a...

Page 5: ...From underneath the burner remove fixings that secure pilot bracket to burner Ease pilot burner assembly clear of burner by moving it slightly downward c Remove four screws securing burner support st...

Page 6: ...o operate it will be necessary to remove sensor bulb of control thermostat from oil This condition can be accomplished by the following procedure a Drain pan b Remove upper panel above door by removin...

Page 7: ...e interruptor h Undo four fixings and remove control chamber base panel j Undo small gland nut sealing capillary tube where it enters fryer pan See Figure 2 k Remove phial guard and ease phial through...