For multiple installations the requirements for individual appliances should be added together. Installation
should be made in accordance with local and/or national regulations applying at the time. A qualified
competent installer MUST BE employed.
The appliance flue discharges vertically through the grille at the top of the unit. There must be no direct
connection of the flue to any mechanical extraction system or the outside air. Siting the unit under a
ventilated canopy is the ideal arrangement. Remember, dirty extraction filters and drip trays may become
a fire hazard due to drip-down on to equipment below. Regular cleaning of extraction filters and drip trays
must be carried out.
1.4 GAS SUPPLY
The incoming service must be of sufficient size to supply full rate gas without excessive pressure drop. A gas
meter is connected to the service pipe by Gas Supplier. Any existing meter should be checked by the
supplier to ensure that it is of adequate capacity to pass required rate of gas for the unit, in addition
to any other gas equipment that has been installed.
The multifunctional control has an in-built governor therefore an external device does not require to be
fitted.
Installation pipework should be fitted in accordance with IGE/UP/2. This should not be smaller than
gas inlet connection.
G3203
- Rp½
(½" BSP)
G3206
- Rp¾
(¾" BSP)
If flexible tube is used, the gas supply tubing or hose shall comply with national requirements in force. The
hose shall not exceed 1.5m length. These will be periodically examined and replaced as necessary.
An isolating cock must be located close to the unit to allow shutdown during an emergency or
servicing. The installation should be checked for gas tightness and purged as specified in IGE/UP/1.
1.5 ELECTRICAL SUPPLY
Not applicable to these units.
1.6 WATER SUPPLY
The appliance is intended for connection to a cold water
(potable water)
supply.
The unit must be
connected in accordance with R160 and that An `Approved` double check valve or some other no less
effective device providing backflow prevention to at least fluid category three shall be fitted at the
point of connection(s) between the water supply and the fitting or appliance.
Supply pressure must be within 2.5 - 7.5 bar.
The appliance must be installed in accordance with EN1717 and national water regulations in force.
A stop cock must be fitted in an easily accessible position on the supply to enable shut off if required
during unit servicing. The pan is designed to be drained manually into a bucket or equivalent.
1.7
Total Heat Inputs
–
Main
Model
kW (net)
Btu/hr (gross)
G3203 Pasta boiler
Nat (I
2
H)
17.7
66,500
G3206 Pasta boiler
Nat (I
2
H)
32.5
122,000
G3203 Pasta boiler
Propane (I
3
P)
17.7
66,500
G3206 Pasta boiler
Propane (I
3
P)
33.2
125,000