The use of flammable solvents must be avoided.

Take care not to damage thermostat boss or tubes

located within stainless steel guards when cleaning.

These are secured to pan base.

NEVER SEARCH FOR A GAS ESCAPE WITH A NAKED

FLAME.

Service

Recommended service frequency - 1 Year.

Contact Serviceline, details on title page of this manual.

SECTION 5 - SPARE PARTS

The following parts may require replacing during the life

of this appliance.

Safety thermostat

Spark igniter

Spark ignition electrode

Operating thermostat

Multifunctional control 

(MFC)

Thermocouple c/w interrupter

Thermopile

Pilot assembly

SECTION 4 - 
CLEANING and MAINTENANCE

Shutting Down after Work

When work is completed, return control knob to pilot

position 

(See Figure 1)

leaving pilot lit if required.

Do not use thermostat knob as a gas control.

Burner will re-light when temperature drops below dial

setting. Before draining, allow water to cool. Burner con-

trol should be OFF to avoid accidental operation.

Daily Cleaning

Isolate gas supply and allow pan contents to cool to a

safe temperature. Insert drain pipe supplied into drain

valve. Open valve and drain water into receptacle.

Close valve and wipe down stainless steel exterior

panels with a cloth, wrung out in hot water and detergent.

Rinse with clean water and dry thoroughly.

Weekly Cleaning

Carry out normal daily cleaning procedure. Remove any

accessories and clean seperately. Fill pan with low

sudsing detergent and hot water, just above normal water

level mark. Allow pan to soak overnight if necessary.

Drain detergent water away. Rinse pan thoroughly with

clean, hot water before wiping dry. Reposition any

accessories and refill pan with water.

Stainless Steel Surfaces

Stainless steel can be easily marked by certain types of

scouring pad including nylon types therefore care should

be exercised when using these. Always rub along in grain

direction when rubbing stainless steel with a cloth.

Safety Precautions

Stop valves will be fitted in the water and gas supply

pipes to unit. User must be familiar with device location

and valve operation to enable isolation in event of

emergency.

Warning

Do not attempt to clean with a jet of water or steam clean. 

Do not use flammable solvents or cleaning aids.

Acid or halogen based descaling liquids 

(e.g. - chlorine)

and cleaning powders should similarly never be used.

If a smell of gas is evident, isolate supply and ventilate

area before calling gas supplier.