208V / 120V Output
Output Configuration Table (208V / 120V)
Terminal 1
Terminal 2
Terminal 3
Terminal 4
Terminal 5 Terminal 6
G2
N22
N11
L22
L11
L12
Ground
0V
0V
120V
120V
88V
Jumper to N11
L2
Jumper N11, L22 & G2
Neutral
Not
Used
L1
*The 120Vac output must not be loaded more than 50% of maximum rated UPS output capacity.
240V / 120V Output
Output Configuration Table (240V / 120V)
Terminal 1
Terminal 2
Terminal 3
Terminal 4
Terminal 5 Terminal 6
G2
N22
N11
L22
L11
L12
Ground
0V
0V
120V
120V
88V
Jumper to N11
L2
Jumper N11, L22 & G2
Neutral
L1
Not
Used
Terminal 1
240V
120V
120V
Terminal 1
208V
120V