EN
1
14
Mounting the hood body
• Screw the two screws
12d
supplied onto the brackets
7.1
.
• Hook the hood body onto the bracket
7.1,
centring it around
the vertical line.
• Use the adjusting screws
12d
underneath the hood to level the
hood body.
12.d
7.1
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 125 mm,
the choice of which is left to the installer.
• To install a ø 125 mm air exhaust connection, insert the re-
ducer flange
9
on the hood body air outlet and the adapting
ring ø120-125
10
on the reducer flange.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove any activated charcoal filters.
9
ø 125
10
ø 150
RECIRCULATION VERSION AIR OUTLET
• Push fit the air outlet fitting
15
onto the air outlet of the hood
body.
• Ensure that the activated charcoal filters have been inserted.
15