20
6.2 ASSEMBLY
6.2.1 Position the appliance and level using feet adjusters as shown below.
TAKE CARE WHEN MOVING AN APPLIANCE FITTED WITH
CASTORS.
6.3 ELECTRIC SUPPLY & CONNECTION
The location of the electrical inlet is as seen in section 5.0. This unit is suitable for AC
supplies only. The standard terminal arrangement is Three phase (400V 3N~) for all
variants.
Live 1 ( Phase 1)
Brown
Live 2 ( Phase 2)
Black
Live 3 ( Phase 3)
Grey
Neutral
Blue
Earth
Yellow/Green
Install an appropriate three phase mains supply cable with a 32A plug.
To install the mains cable, remove rear access panel as shown in section 7.1 and feed the
cable through and connect to the terminal block.