![Falcon E702S Installation And Servicing Instrucnion Download Page 3](http://html1.mh-extra.com/html/falcon/e702s/e702s_installation-and-servicing-instrucnion_3269548003.webp)
SECTION 1 - INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH
H A V E B E E N P R O T E C T E D B Y T H E
MANUFACTURER ARE NOT TO BE ADJUSTED
BY THE INSTALLER
1.2 SITING
The units are suitable for installation upon any flat,
horizontal surface. Adjustable feet to facilitate
levelling within a limited range. Position oven in
desired location and use a suitable spanner to level.
Sufficent clearance should be left around unit to allow
turning for maintenance purposes.
1.3 ELECTRICAL SUPPLY and CONNECTION
These ovens are designed to be connected to a
single phase 230V/50hz AC supply. The unit power
rating is 2.65kW. The mains lead is fitted with a
moulded fused plug to BS1363 with 13 amp fuse
fitted. The mains lead wires are coloured in
accordance with the following code:
Green and Yellow
EARTH
Blue
NEUTRAL
Brown
LIVE
These wires should be connected as follows:
EARTH to terminal marked E
NEUTRAL to terminal marked N
LIVE to terminal marked L
Warning - This appliance MUST be earthed!
Any replacement supply cable must be 1.5mm
2
, cord
code designation 245 IEC 57 (Cenelec H05 RN-F).
For internal connection, outer sheathing must be
stripped 140mm from cable end. Live and Neutral
conductors must be trimmed so that earth conductor
is longer by 50mm. Pass inlet cable through rear
panel cord grip and ensure cable is routed without
leaving excessive free length inside unit.
1.4 INSTRUCTION TO USER
Upon completion of installation, the correct method of
operation should be demonstrated to kitchen staff.
Location of the main isolating switch should also be
indicated, to be used in event of an emegency or
during cleaning.
SECTION 2 - SERVICING and
MAINTENANCE
Warning
BEFORE ATTEMPTING TO UNDERTAKE ANY
MAINTENANCE TASK. ISOLATE THE POWER AT
THE MAIN SWITCH AND TAKE STEPS TO
ENSURE THIS CANNOT BE INADVERTENTLY
SWITCHED ON.
2.1 OVEN CONTROL PANEL
2.1.1 Control Panel
Undo two fixings on underside of oven until location
pins allow panel to drop forward.
2.1.2 To Remove Rear Panel
a) Slacken fixings behind elongated slots at top of
panel.
b) Lift panel clear of these fixings.
c) Replace in reverse order.
2.1.3 To Remove Outer Casing
a) Remove rear panel. See Sections 2.1.2.
b) Undo fixings that secure casing to base.
c) Remove top and bottom hinge fixing screws.
d) Pull casing sides away from base and lift casing.
e) Replace in reverse order.
2.1.4 To Remove Oven Back Baffle
a) Remove oven shelves.
b) Raise shelf hangers from keyhole slots and
remove.
c) Slacken back baffle fixing screws.
d) Raise baffle on keyhole slots to remove.
e) Replace in reverse order.
2.1.5 To Remove Elements
a) Remove back baffle. Refer to Section 2.1.4.
b) Remove rear panel as detailed in Section 2.1.2.
c) Undo element connections at oven rear.
d) Remove fixings at rear of oven cavity.
e) Withdraw element.
f) Replace in reverse order and ensure earth tabis
connected.
2.1.6 To Remove Fan
a) Remove baffle. Refer to Section 2.1.4.
b) Remove rear panel. Refer to Section 2.1.2.
c) Undo fan wires.
d) Remove earth lead.
e) Undo impeller retaining nut (LH thread) and
remove impeller.
f) Undo fixings that secure motor to oven rear and
withdraw.
g) Replace in reverse order.
MODEL
WIDTH
mm
DEPTH
mm
HEIGHT
mm
WEIGHT
kg
WEIGHT
lbs
E7202S
667
570
550
50
110
E7202 BE1
667
570
550
50
110
E7202 BE2
667
570
550
50
110
E7202 BF1
667
570
550
50
110
E7202 BF1
667
570
550
50
110
1.1 MODEL NUMBER, NETT WEIGHTS