IMPORTANT INFORMATION

Warranty Policy Shortlist

Warranty does not cover :-

Correcting faults caused by incorrect installation of a product.

Where an engineer cannot gain access to a site or a product.

Repeat commission visits.

Replacement of any parts where damage has been caused by misuse.

Engineer waiting time will be chargeable.

Routine maintenance and cleaning.

Gas conversions i.e. Natural to Propane gas.

Descaling of water products and cleaning of water sensors where softeners/ conditioners are not fitted, 

or are fitted and not maintained.

Blocked drains

Independent steam generation systems.

Gas, water and electrical supply external to unit.

Light bulbs

Re-installing vacuum in kettle jackets.

Replacement of grill burner ceramics when damage has been clearly caused by misuse.

Where an engineer finds no fault with a product that has been reported faulty.

Re-setting or adjustment of thermostats when unit is operating to specification.

Cleaning and unblocking of fryer filter systems due to customer misuse.

Lubrication and adjustment of door catches.

Cleaning and Maintenance

• Cleaning of burner jets

• Poor combustion caused by lack of cleaning

• Lubrication of moving parts

• Lubrication of gas cocks

• Cleaning/adjustment of pilots

• Correction of gas pressure to appliance.

• Renewing of electric cable ends.

• Replacement of fuses

• Corrosion caused by use of chemical cleaners.

Summary of Contents for E3830

Page 1: ...of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDU...

Page 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where...

Page 3: ...ricity supply it must be correctly positioned and levelled Levelling is effected by turning the lower area of the adjustable legs If desired feet that allow floor fixing may be specified at time of or...

Page 4: ...ll glands which must not be overtightened The phial must be fixed in position within pan before tightening gland The phial tip should protrude from protective tube by 33mm Thermostat capillary tube mu...

Page 5: ...E3830 WIRING DIAGRAM...

Page 6: ...E3860 WIRING DIAGRAM 4 Element Version...

Page 7: ...6 3 2 1 19 26 AMBER NEON 15 21 RED NEON 17 21 OPERATING STAT 18 20 CONTACTOR A1 A2 7 9 8 10 15 17 28 18 11 TERMINAL BLOCK 28 14 TILT SWITCH SAFETY STAT 20 14 ELEMENT 9 ELEMENT 8 ELEMENT 7 ELEMENT BOX...

Page 8: ...5kW 230V 14 13 5 RED NEON 12 15 A1 A2 10 SAFETY STAT TRIP POINT 230 C OPERATING STAT 0 C 190 C 9 16 11 TILT SWITCH LOWERED POSITION 18 6 15 AMBER NEON 1 2 3 4 5 6 7 5 2 1 9 16 11 6 18 12 15 10 13 14 7...

Page 9: ...AFETY STAT TRIP POINT 230 C 16 17 A1 A2 17 21 RED NEON 19 23 26 7 8 CONTACTOR IMO MC 24 S 00 1 3 1 3 5 6 4 2 N L2 L1 L3 2 2 18 25 10 24 9 9 10 16 23 24 25 26 ELEMENT POSITIONS ARE WHEN VIEWED FROM FRO...

Page 10: ...17 21 RED NEON 19 23 25 8 10 CONTACTOR IMO MC 24 S 00 1 3 1 3 5 6 4 2 N L2 L1 L3 2 2 18 26 11 24 9 9 24 ELEMENT POSITIONS ARE WHEN VIEWED FROM FRONT OF APPLIANCE H1 OUTSIDE LH ELEMENT 3 65kW 230V H2 I...