SECTION 1 - INSTALLATION
1.2 SITING
The appliance must be installed on a firm counter or
table or alternatively on the special purpose made
floor stand supplied by Falcon.
If either appliance requires to be installed in close
proximity to a wall, partition, etc. a clearance of 25mm
at the rear and sides is recommended.
A vertical clearance between the hotplates and any
overlying combustible surface of 900mm should be
allowed and Fire Regulations must be complied with.
1.3 ELECTRICAL SUPPLY
The E350/32 is suitable for connection to a single
phase AC supply only.
The E350/33 is designed for connection to either a
3 phase/4 wire AC supply or to a single phase AC
supply. (See note below.)
The cable entry is located at the rear of the appliance
and is suitable for 20mm conduit. The connection to
the mains electricity supply must be made through a
suitable isolating switch with a contact separation of
at least 3mm in all poles. All wiring must be executed
in accordance with the relevant regulations listed on
the cover of this document.
Warning
THESE APPLIANCES MUST BE EARTHED.
A suitable terminal is provided within compartment
which should be used for this purpose.
Note
When connecting the E350/33 unit to a single phase
supply, the three line terminals must be connected
together using the wire links provided. It is important
that the links and incoming supply cable are
connected exactly as shown in the following diagram.
N
L1
L2
L3
Supply Cables
N
L1
1.4 ELECTRICAL RATINGS
The electrical ratings are as stated on the appliance
data plate.
Note
The hotplates embody a temperature limiting device
which automatically cuts off part of the element circuit
should the plate become overheated due to being left
on without a pot on it.
Controls
6 heat switches.
SECTION 2 - ASSEMBLY and
COMMISSIONING
a) Place the appliance in position and carefully level it
by using the feet adjusters if it is to be mounted on
a counter or table. If the unit is required to be
mounted on the special purpose stand, please
refer to the instructions supplied with that
component.
b) The appliance is supplied complete and ready to
connect to the mains.
c) To gain access to the terminals, proceed as
follows:
Remove the two screws in the upper flange of the
control panel (i.e. below the front hob).
Move the panel forward at the top until it clears the
hob and lift it slightly upward to release the lower
fixings and remove the panel.
d) The terminals are now accessible. The supply
cables can be fed through the in-built conduit tube.
e) After connecting to the supply, replace the control
panel and test the unit. Check that all hotplates,
pilot lamps, etc. function correctly.
SECTION 3 - SERVICING
BEFORE ATTEMPTING ANY MAINTANANCE,
ISOLATE THE APPLIANCE AT THE MAIN SWITCH
AND TAKE STEPS TO ENSURE IT IS NOT
INADVERTENTLY SWITCHED ON.
When ordering spares please quote the model
number, serial number and voltage as stated on the
data plate.
3.1 CONTROL PANEL - TO REMOVE
Remove the two screws in the upper flange of the
panel, below the front of the hob. Move the panel
forward at the top until itr clears the hob and lift it
slightly upward to release the lower fixings. Remove
the panel complete with switches.
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER
ARE NOT TO BE ADJUSTED BY THE INSTALLER
MODEL
WIDTH
mm
DEPTH
mm
HEIGHT
mm
WEIGHT
kg
WEIGHT
lbs
E350/32
350
650
305
23
52
E350/33
700
650
305
38
84
1.1 MODEL NUMBER, NETT WEIGHTS
and DIMENSIONS