Warranty does not cover :-
Correcting faults caused by incorrect installation of a product.
Where an engineer cannot gain access to a site or a product.
Repeat commission visits.
Replacement of any parts where damage has been caused by misuse.
Engineer waiting time will be chargeable.
Routine maintenance and cleaning.
Gas conversions i.e. Natural to Propane gas.
Descaling of water products and cleaning of water sensors where softeners/conditioners are not fitted,

or are fitted and not maintained.
Blocked drains.
Independent steam generation systems.
Gas, water and electrical supply external to unit.
Light bulbs.
Re-installing vacuum in kettle jackets.
Replacement of grill burner ceramics when damage has been clearly caused by misuse.
Where an engineer finds no fault with a product that has been reported faulty.
Re-setting or adjustment of thermostats when unit is operating to specification.
Cleaning and unblocking of fryer filter systems due to customer misuse.
Lubrication and adjustment of door catches.
Cleaning and Maintenance:

Cleaning of burner jets

Poor combustion caused by lack of cleaning

Lubrication of moving parts

Lubrication of gas cocks

Cleaning/adjustment of pilots

Correction of gas pressure to appliance.

Renewing of electric cable ends

Replacement of fuses

Corrosion caused by use of chemical cleaners.

Summary of Contents for E350/32

Page 1: ...ration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommend that a Maintenance Contract be...

Page 2: ... Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems due to cus...

Page 3: ...y cuts off part of the element circuit should the plate become overheated due to being left on without a pot on it Controls 6 heat switches SECTION 2 ASSEMBLY and COMMISSIONING a Place the appliance in position and carefully level it by using the feet adjusters if it is to be mounted on a counter or table If the unit is required to be mounted on the special purpose stand please refer to the instru...

Page 4: ...ust be replaced adopting the following procedure Remove the control panel as detailed in Section 3 1 Pull off the lamp connections Undo the nut which secures the lamp at the rear and remove 3 4 HOTPLATE TO REPLACE Remove the control panel as detailed in Section 3 1 Slacken the two nuts inside the ends of the chrome plated side trims Pull the hob assembly forward to release the front fixing and swi...

Page 5: ...4 3 1 2 5 P 2 P 1 P 3 4 3 1 2 5 P 2 P 1 P 3 4 3 1 2 5 P 2 P 1 P 3 4 3 1 2 5 P 2 P 1 P 3 H o t p l a t e s S i x P o s i t i o n S w i t c h e s R e d N e o n E 3 5 0 3 3 W I R I N G D I A G R A M ...