background image

1.3  ELECTRICAL SUPPLY

Warning

THIS APPLIANCE MUST BE EARTHED

A cable entry suitable for 20mm conduit is situated in the

unit rear at the RH side. To gain access to the terminals,

the RH side panel must be removed. 

Mains connection must be made via a suitably rated

isolating switch with a contact separation of at least 3mm

on all poles. The use of heat resistant cable is

recommended. Wiring should be in accordance with

current IEE Wiring Regulations.

Particular attention must be paid to providing   adequate

and effective earthing using the earth terminal provided.

1.4 ELECTRICAL LOADINGS

The electrical loading is stated on unit data plate. This is

located on RH outer side panel.

SECTION 2 - ASSEMBLY

2.1 ASSEMBLY

Note

Mounting accessories are available. Contact Falcon

Sales, an equipment distributor or place of purchase.

a) Unpack unit and place it in position using separate

mounting accessories.

b) Mounting accessories should be assembled according

to separate instructions provided.

c) Check the following listed parts are included:-

Brander plate

Brander drip trough

Grid shelf

Grid shelf handles

Drip tray

d) The grid shelf handles are supplied separately and

must be screwed on to grid shelf arms.

1.1 MODEL NUMBERS, NETT WEIGHTS 

and DIMENSIONS

1.2  SITING

Installation should be made in accordance with local

and/or national regulations applying at the time and a

competent installer must be employed. There should be

a clearance of 200mm from any wall or object liable to

damage from overheating and 75mm clearance should

be left from any wall to allow removal of the side panels

for maintenance.

In the event of a requirement to position this appliance in

close proximity to a wall, partion, kitchen furniture or

decorative finish, etc. it is recommended that these be

constructed of a non-combustible material. If this is not

possible then these surfaces require to be clad in a

non-combustible, heat insulating material. Close

attention must be paid to fire prevention regulations.

The grill should be installed level and in a well lit position

with adequate ventilation. 

Mounting

The grill can be mounted upon:

Floorstand.

Legs: 300mm high.

Wall bracket.

Note

E3532 model is not compatible with old-style plate

shelves.

Model

Width

(mm)

Depth

(mm)

Height

(mm)

Weight

(kg)

E3512 Grill

730

560

505

55

E3532 Grill

785

355

350

30

SECTION 1 - INSTALLATION

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER 

ARE NOT TO BE ADJUSTED BY THE INSTALLER.