![Falcon DOMINATOR PLUS Series Installation And Servicing Instructions Download Page 3](http://html1.mh-extra.com/html/falcon/dominator-plus-series/dominator-plus-series_installation-and-servicing-instructions_3275918003.webp)
SECTION 1 - INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE
MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER.
1.1 MODEL NUMBERS, NETT WEIGHTS and DIMENSIONS
Model
Width
(mm)
Depth
(mm)
Height
(mm)
Weig
ht
(kg)
E3830 Fryer
300
770
890
45
E3860 Fryer
600
770
890
73
E3865 Fryer
600
770
890
85
1.2 SITING
Before connecting appliance to electricity supply, it must be correctly positioned and levelled. Levelling is effected by
turning the lower area of the adjustable legs. If desired, feet that allow floor-fixing may be specified at time of
order.
1.3 ELECTRICAL CONNECTION
The unit is designed for use on AC supplies only and terminals are normally arranged for either 2 phase
operation
(E3830 model)
or 3 phase
(E3860 & E3865 models)
.
If single phase supply has been specified, a bridging link is provided with the appliance and should be connected as
detailed below.
Cable entry is located at appliance rear in the form of a cable gland.
A suitably rated isolating switch with contact separation of at least 3mm in all poles must be installed. All wiring must be
executed in accordance with regulations listed on title page of this document.
Warning - This appliance must be earthed.
1.4 ELECTRICAL RATINGS
The electrical rating is stated on appliance data plate.
Model
L1
L2
L3
E3830 Fryer
21.7A
21.7A
E3860 Fryer
21.7A
43.4A
27.1A
E3865 Fryer
21.7A
43.5A
21.74
Summary of Contents for DOMINATOR PLUS Series
Page 7: ...E3830 WIRING DIAGRAM...
Page 8: ...E3830 CIRCUIT DIAGRAM...
Page 9: ...E3860 WIRING DIAGRAM...
Page 10: ...E3860 CIRCUIT DIAGRAM...
Page 11: ...E3865 WIRING DIAGRAM...
Page 12: ...E3865 CIRCUIT DIAGRAM...