Contemporary Falcon Cooker Hoods 

Revision: 02/02/2009 

 

Installation, Operation & Maintenance Instructions 

 
SECTION 1 

INTRODUCTION 

  

SECTION 2 

EXTRACTION PERFORMANCE 

  

SECTION 3 

IMPORTANT INFORMATION 

  

SECTION 4 

INSTALLATION 

  

 

4.1 Removing Grease Filters 

 

4.2 Blower Exhaust Position 

 

4.3 Duct Installation 

 

4.4 Fixing the Hood to the Wall 

 

4.5 Connecting the Ducting 

 

4.6 Electrical Installation 

SECTION 5 

OPERATING INSTRUCTIONS 

  

SECTION 6 

MAINTENANCE 

  

SECTION 7 

SPECIFICATIONS 

  

FIGURE 1: 

DIMENSIONS AND FIXING DETAILS 

  

 

SECTION 1. INTRODUCTION 

Your range cooker is a semi-professional unit which gives you the power and flexibility to 
realise your full potential in the kitchen. Inevitably, during the cooking process, there will 
be heat, vapours and fumes produced. Your Falcon extractor has been designed to 
complement the range cooker both in looks and performance in order to create the ideal 
environment for creative cooking.  

 

SECTION 2. EXTRACTION PERFORMANCE 

The most important influence on the  performance of the extractor is the design of the 
ducting which takes the exhaust air from the extractor to the outside wall louvre. The duct 
route should be a prime consideration during the initial stages of the kitchen design. 
Please note the following:  

 

The extractor is provided with a spigot suitable for connecting 150mm diameter 
duct.  

 

Note: 150mm is the minimum duct diameter consistent with efficient extraction.  

 

The exhaust duct route length should be kept as short as possible with as few 
bends as possible.  

 

The most efficient configuration is to duct straight through an outside wall so try to 
position the cooker against an outside wall when designing your kitchen layout.  

 

The hood can be vented either to the top exhaust or the rear exhaust position. Use 
the position which gives the shortest duct route length and least number of bends. 
(The blower will need to be rotated for ducting directly through the rear exhaust 
position.) 

 

A route with more than two 90 bends will significantly degrade the performance of 
the  extraction system. If possible, avoid having a 90 bend at the extractor exhaust 
spigot; keep bend radii as large as possible to maintain a smooth airflow without 
vortices; avoid kinks in flexible ducting; pull flexible ducting taut over straight runs to 
ensure that the internal surface is as smooth as possible. 

 

SECTION 3. IMPORTANT INFORMATION 

The following minimum headroom is required to accommodate the cooker and hood:  

For a small charge customised replacement chimneys can be produced to suit your 
requirements.  

The minimum distance between the range hob burners and the bottom of the extractor is 
essential to prevent overheating of the extractor and its components. 

If you are fitting a Falcon splashback then the cooker-to-hood clearance is dictated by the 
splashback height of 800mm excluding flanges. 

Please also note that a 90 bend in the flexible ducting will require 215mm minimum head-
room to give a smooth radius with no kinking. 

Requirements of the relevant authorities concerning the discharge of exhaust air must be 
complied with. 

Attention:  

This appliance requires an earth connection.  

Ensure that the supply voltage corresponds to that marked on the rating label inside the 
extractor. 

The extractor must be isolated from the electrical supply before carrying out any cleaning 
or maintenance operations.  

Pay particular attention to fire risk when frying. To minimise the risk of fire, all 
instructions relating to cleaning the grease filters and removing grease deposits 
must be adhered to.  

Do not flamb

é under the extractor.

 

 

SECTION 4. INSTALLATION 

4.1 Removing the Grease Filter(s) 

Place extractor on its backplate on a horizontal surface. 

To remove the grease filters pull/lift the filter release lever away from the hood base. This 
releases the retaining clips allowing the filter to be carefully lifted away from the hood. 
Take care not to scratch the hood. 

The four internal fixing holes, blower assembly and spigot blanking plate can now be 
accessed through the openings in the baseplate. (See Figure 1). 

4.2 Blower Exhaust Position 

The hood can be vented either to the top exhaust or the rear exhaust position. Each 
exhaust position has 4 studs onto which can be bolted either the blower assembly or a 
blanking plate. 

Bolt blower assembly to chosen exhaust position and the blanking plate to the unused 
position. 

When changing the exhaust position, care should be taken not to excessively pull or twist 
the cable attached to the blower. 

4.3 Duct Installation 

Make a hole in the wall or ceiling to take the 150mm diameter ducting from the extractor 
exhaust spigot to the outside. 

The exhaust duct route length should be kept as short as possible with as few bends as 
possible - see Section 2. 

Knock a hole in the outside wall to match the internal measurements of the louvre. 

4.4 Fixing the Hood to the Wall  

If you are fitting a Falcon Splashback it must be fitted before the hood. 

Full instructions for mounting the hood are given in Figure 1.  

Note: The decorative chimney can be removed to ease handling of the hood. 

The supporting wall must be of good quality, have an even surface and be sturdy enough 
to support the extractor. 

Fixings must be used which are suitable for the type of wall construction. 

4.5 Connecting the Ducting  

Connect ducting to extractor exhaust spigot. This may have to be done prior to fixing the 
extractor to the wall. You may find this easier with the chimney removed. The chimney is 
attached using M4 machine screws which can be accessed through the filter opening(s). 

When the extractor is in position, check that the duct has not been flattened or kinked 
along its route. 

Connect the ducting to the wall louvre spigot or alternative outside termination. 

Secure the louvre to the outside wall. Ensure that any air fins are directed downwards.  

Refit the grease filter(s). 

4.6 Electrical Installation  

The extractor is a stationary appliance designed to be connected by fixed wiring to the 
electrical supply. A competent electrical technician must perform the electrical installation. 

The extractor must be fed from a 230Vac single phase electrical supply using a switched 
spur fitted with a 3A fuse. The spur should be located adjacent to the extractor/cooker so 
that the supply can be disconnected from the extractor using the switch. The means of 
disconnecting from the supply must have a minimum contact separation of 3mm in all 
poles. Alternatively a means of disconnection in the fixed wiring according to the relevant 
wiring rules must be fitted.  

A supply cord for connecting the spur to the extractor is included. 

The mains supply is connected to the free end of this cord as follows: 

Cooker-to-hood clearance (min):

 

800 mm

 

Hood height including chimney:

 

550

950 mm

 

Minimum ceiling height with standard chimney:

 

2290mm

 

INCOMING SUPPLY CORD CONNECTIONS

 

Core

 

Core Colour

 

Live

 

Brown

 

Neutral

 

Blue

 

Protective Earth

 

Green/Yellow

 

The exhaust air must not be discharged into a flue which is used for exhausting 
fumes from appliances supplied with energy other than electricity, e.g. oil or gas-
fired central heating boilers, gas-fired water heaters, etc. 

Adequate ventilation of the room must be provided when the cooker, extractor and 
appliances supplied with energy other than electricity (e.g. gas-fired or oil-fired heat-
ers, etc.) are used simultaneously. The room must be provided with vents to allow a 
constant flow of fresh air.  

Warning 

Proper care must be taken to ensure that the negative pressures caused by high 
performance extraction systems do not adversely affect the safe operation of certain 
types of fuel-burning appliances (gas, oil or solid fuel), including those installed in 
the kitchen and possibly also those installed in other parts of the house. 

Where such fuel-burning appliances are installed, adequate ventilation MUST be 
provided in the room of installation, located and sized such that the negative pres-
sure in the room created by the extractor does not exceed 4Pa. 

In case of doubt, do not operate the extractor and fuel-burning appliance(s) simulta-
neously and consult an appropriate (for the fuel type) expert for advice.

 

 

ELECTRICAL HAZARD 

DISCONNECT ELECTRICAL SUPPLY 

BEFORE PROCEEDING FURTHER 

Summary of Contents for CT1090

Page 1: ...lcon Cooker Hoods Contemporain Hottes Falcon Moderne Falcon Dunstabzugshauben Eigentijds Falcon Afzuigkappen Modern Falcon K por DEUTSCHE 6 Montage Gebrauchs Wartungsanleitung SVENSK 10 Installations...

Page 2: ...ccessed through the openings in the baseplate See Figure 1 4 2 Blower Exhaust Position The hood can be vented either to the top exhaust or the rear exhaust position Each exhaust position has 4 studs o...

Page 3: ...ION 7 SPECIFICATIONS Hood weights Blower airflow nominal 1 000 m3 hr Noise level 56dBA Supply voltage 230V 50Hz Halogen lamp voltage 12V Blower power input 1 300W Halogen lamp power 2 x 20W Total powe...

Page 4: ...goujons auxquels on peut positionner soit le montage ventilateur soit une plaque Positionner le ventilateur la position d chappement d sir e et la plaque la position non utilis e En changeant la posi...

Page 5: ...e 1 1 Marquez une ligne horizontale A dans la position d sir e de la base de la hotte 2 Marquez une ligne centrale verticale du fourneau et la hotte B 3 Marquez les centres de trous de fixation comme...

Page 6: ...Die Haube kann entweder durch den oberen oder den hinteren Abluftausgang bel ftet werden Jeder Abluftausgang besitzt 4 Gewindebolzen an denen entweder die Gebl segruppe oder eine Abdeckplatte angeschr...

Page 7: ...tion LEUCHTEN EIN AUS 0 1 GEBL SE EIN STUFE 1 min GEBL SE AUS sofortiger Stopp 2 GEBL SE EIN STUFE 2 3 GEBL SE EIN STUFE 3 4 GEBL SE EIN STUFE 4 max GEBL SE AUS MIT 10 MINUTEN VERZ GERUNG zum Absaugen...

Page 8: ...izontaal oppervlak Verwijder de vetfilters dmv het oplichten van de hendel aan de afzuigkap Haal de filters voorzichtig uit de afzuigkap zonder de kap te beschadigen U kunt nu bij de interne ophanging...

Page 9: ...igcapaciteit nominale 1 000 m3 hr Geluidsnivo 56dBA Elektrische aansluiting 220 240V 50Hz Halogeen lamp voltage 12V Motor 1 300W Halogeen lamp verlichting 2 x 20W Totale elektrische aansluiting 340W Z...

Page 10: ...heten vid det valda utloppet och t ckplattan p det andra utloppet Var f rsiktig n r du byter utloppsl ge s att du inte i on dan drar i eller vrider kabeln som r f st vid fl kten K pan levereras monter...

Page 11: ...ing 220 240V 50Hz Halogenlampsp nning 12V Fl kteffekt 1 300W Halogenlampeffekt 2 x 20W Total effekt 340W Rekommenderad s kring f r elmatning 3A Fl ktens muffdiameter 150mm CT900 26Kg CT1092 29Kg knapp...

Reviews: