33
INSTALLATION
Check the appliance is electrically safe when you have finished.
Fixed Wiring
n
n
Disconnect from the mains supply.
For connection to fixed wiring, i.e. flexible conduit, remove
the electrical terminal cover on the back panel (Fig. 7.13).
Fit the conduit box to the cooker using the two M5 screw
fittings located at the top of the box. Remove the M4 screw
from the base, and fix to the cooker, via the fitting through
the back of the conduit box (Fig. 7.14).
The conduit box cover is reversible. Fit the reducer plate if
required (Fig. 7.15). Feed the cable through the conduit box
and secure in place with the cable clamp.
Connect the mains cable to the correct terminals for your
electrical supply type (Fig. 7.16). Check that the links are
correctly fitted and that the terminal screws are tight.
Fit the cover to the conduit box.
Conduit box
M4 screw
M5 screws
Reducer plates
Reversible conduit box cover
ArtNo.132-0002 - 3 phase 240/415Vac 50Hz
3-phase 400 V
AC
50 Hz
Fig. 7.13
Fig. 7.14
Fig. 7.15
Fig. 7.16