SECTION 1 

– INSTALLATION 

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE 
MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 

 

 

 

1.1 

MODEL NUMBER, NETT WEIGHT and 

DIMENSIONS 

This manual refers to the following models 

– 

 
Note - Pot racks not included 

1.2 SITING 

Each  unit  must  be  fixed  onto  a  firm,  level,  heat 
resistant, non-combustible floor in a well lit position. 

Units  are  best  situated  below  a  ventilating  canopy  to 
remove cooking vapours etc. 

Installation  must  be  made  in  accordance  with  local 
and/or national regulations applying at the time. Close 
attention  must  be  paid  to  fire  prevention  regulations 

also. A competent installer must be employed. 

Where  the  appliance  is  to  be  positioned  close  to  a  wall,  partition,  kitchen  furniture,  decorative  finish  etc.,  of 
combustible construction, there should be a clearance all round of 150mm. 

In addition,  this  allows  removal  of  side  panels  for  servicing.  The  walls  or  partitions must  be                                  non-
combustible  or  clad  with  a  similar  material  should  the  appliance  be  required  to  be  positioned  closer  than 
150mm. 

1.3 ELECTRICITY SUPPLY 

These  appliances  are  suitable  for  AC  supplies  only.  On  the  range,  the  standard  terminal  arrangement  is  for  3 
phase / 4 wire connection but by linking the 3 line terminals, the unit can be connected to a single phase supply. 
Suitable links are provided when single phase supply is specified at the time of ordering. 

Note 

When connecting to a single phase supply, the three line terminals must be connected together using the wire 
links  provided. It  is  important  that the  links  and  incoming  supply  cable  are  connected  exactly  as  shown  in  the 
following sketches. 

General purpose ovens are single-phase operation only. 

Each oven in a two tier unit has an independent connection point. 

A  suitably  rated  isolating  switch  with contact        separation  of  at least  3mm  in  all  poles,  must  be  installed. The 
wiring must be executed in accordance with the relevant regulations listed on the front cover of this manual.  

 

 

 

 

 

 

 

 

MODEL 

WIDT

mm 

DEPT

mm 

HEIGH

mm 

WEIGH

kg 

E1006 (Three 

Solid 

Hotplates) 

900 

850 

890 

227 

E1016 

General 

Purpose 

Oven 

900 

850 

890 

150 

E1016/2 

Two Tier 

Oven 

900 

850 

1740 

300 

E1026 (Three 

Solid 

Hotplates) 

900 

850 

890 

170 