SECTION 1
– INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE
MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER
1.1
MODEL NUMBER, NETT WEIGHT and
DIMENSIONS
This manual refers to the following models
–
Note - Pot racks not included
1.2 SITING
Each unit must be fixed onto a firm, level, heat
resistant, non-combustible floor in a well lit position.
Units are best situated below a ventilating canopy to
remove cooking vapours etc.
Installation must be made in accordance with local
and/or national regulations applying at the time. Close
attention must be paid to fire prevention regulations
also. A competent installer must be employed.
Where the appliance is to be positioned close to a wall, partition, kitchen furniture, decorative finish etc., of
combustible construction, there should be a clearance all round of 150mm.
In addition, this allows removal of side panels for servicing. The walls or partitions must be non-
combustible or clad with a similar material should the appliance be required to be positioned closer than
150mm.
1.3 ELECTRICITY SUPPLY
These appliances are suitable for AC supplies only. On the range, the standard terminal arrangement is for 3
phase / 4 wire connection but by linking the 3 line terminals, the unit can be connected to a single phase supply.
Suitable links are provided when single phase supply is specified at the time of ordering.
Note
When connecting to a single phase supply, the three line terminals must be connected together using the wire
links provided. It is important that the links and incoming supply cable are connected exactly as shown in the
following sketches.
General purpose ovens are single-phase operation only.
Each oven in a two tier unit has an independent connection point.
A suitably rated isolating switch with contact separation of at least 3mm in all poles, must be installed. The
wiring must be executed in accordance with the relevant regulations listed on the front cover of this manual.
MODEL
WIDT
H
mm
DEPT
H
mm
HEIGH
T
mm
WEIGH
T
kg
E1006 (Three
Solid
Hotplates)
900
850
890
227
E1016
General
Purpose
Oven
900
850
890
150
E1016/2
Two Tier
Oven
900
850
1740
300
E1026 (Three
Solid
Hotplates)
900
850
890
170