7
Release For Service
7a Remove all tools, installation equipment and debris from the vicinity of the door.
7b
MANDATORY: Install all Safety, Traffic Control and Instruction Labels onto the door, as required.
Failure to do this will leave the INSTALLER LIABLE for any accidents that occur.
7c Give verbal instruction on how to properly operate the door to the owner or person in charge.
7d Give verbal instruction to the owner or person in charge on periodic inspection of the door for the following:
• Occasional damage
• Developing problems
• Minor preventative maintenance
7e Provide the owner or person in charge with a contact name and phone number to call for future service and
maintenance.
IMPORTANT
Be sure to install all Safety, Traffic Control and Instruction
Labels onto the door, as required.
8
Falcon Software
8a Operation:
1. Sizing:
From start-up (sizing), the door will activate via:
Main Input (Main Act and Main Act Com).
The first motion of the door will be towards the Door Open position. The speed during Sizing is automatic and cannot be set from a
potentiometer.
The door drives to full open and the system sets the open counter to full open.
The door closes at Closing Speed. The system sets the closed counter to Full Closed when the latch goes up at the Closed position.
The system calculates all other parameters required for normal operation based on the two values of Full Open and Full Closed.
Summary of Contents for 8230