2.3.2
Potentiometer
a)
Remove
control
panel.
b)
Remove
control
cover
plate
by
undoing
four
fixings
on
E1808
model
and
five
on
E1838
and
E1848
models.
Disconnect
potentiometer
leads
at
PCB.
c)
Pull
off
potentiometer
knob
and
undo
securing
screws
to
allow
potentiometer
and
bracket
to
be
withdrawn.
d)
Undo
allen
screws
and
pull
extended
spindle
away
from
potentiometer.
e)
Undo
nut
that
secures
potentiometer
to
bracket.
f)
Replace
in
reverse
order.
g)
To
check
thermostat
calibration
select
a
temperature
of
190Žo
C
and
allow
the
oil
to
heat
up.
With
a
suitable
thermometer
or
thermocouple,
immersed
25mm
below
oil
surface
at
pan
centre.
Check
that
oil
temperature
corresponds
with
setting.
2.3.3
High
Temperature
Limit
Device
This
device
is
set
to
cut
power
to
element
should
oil
temperature
exceed
230Žo
C.
Manual
intervention
is
required
to
reset
control
in
the
event
of
a
failure.
To
Reset
Open
fryer
door
and
push
button
that
protrudes
from
underside
of
control
chamber.
To
Replace
a)
Remove
control
panel.
b)
Remove
controls
cover
plate.
c)
Disconnect
electrical
leads
from
safety
thermostat.
d)
Undo
fixings
that
secure
safety
thermostat
to
flange
on
control
panel.
e)
Withdraw
safety
thermostat
probe
by
undoing
nut
from
boss
on
fryer
body.
Ensure
that
oil
has
been
drained
from
pan.
Withdraw
capillary
and
probe
from
pan.
f)
Replace
in
reverse
order.
Operation
of
the
high
temperature
limit
device
must
be
checked
at
regular
intervals
adopting
the
following
procedure:
a)
As
per
items
2(a)
and
(b)
above.
b)
Bridge
thermocouple
connection
on
PCB
with
a
short
piece
of
wire
(see
wiring
diagram).
c)
Fill
pan
with
oil
to
indicated
level
mark
and
install
a
means
of
measuring
the
oil
temperature.
Measuring
sensor
must
be
placed
at
geometric
pan
centre,
25mm
below
oil
surface.
d)
Switch
unit
on
and
observe
rising
oil
temperature.
If
unit
functions
properly,
high
temperature
limit
device
will
cut
the
power
supply
when
temperature
of
oil
is
between
220Žo
C
and
225Žo
C.
Should
device
fail
to
operate
at
a
maximum
temperature
of
230Žo
C,
shut
unit
OFF
immediately
by
pressing
OFF
switch
on
control
panel.
Undertake
investigations
to
detect
fault.
e)
Once
satisfied
that
high
temperature
limit
device
is
functioning
correctly,
remove
bridge
connection
from
PCB.
Replace
all
panels
and
push
re
‐
set
button
to
activate
control.
2.4
COOLING
FAN
a)
Remove
control
panel.
b)
Remove
controls
cover
plate.
c)
Disconnect
electrical
leads.
d)
Undo
four
fixings
and
remove
fan.
e)
Replace
in
reverse
order.