SECTION 1 – INSTALLATION 

UNLESS

 

OTHERWISE

 

STATED,

 

PARTS

 

WHICH

 

HAVE

 

BEEN

 

PROTECTED

 

BY

 

THE

 

MANUFACTURER

 

ARE

 

NOT

 

TO

 

BE

 

ADJUSTED

 

BY

 

THE

 

INSTALLER

 

 

 

1.1

 

MODEL

 

NUMBER,

 

NETT

 

WEIGHTS

 

and

 

DIMENSIONS

 

 

MODEL

 

WIDTH

 

DEPTH

 

HEIGHT

 

WEIGHT

 

E1808

 

300mm

 

850mm

 

900mm

 

51kg

 

E1838

 

600mm

 

850mm

 

900mm

 

78kg

 

E1848

 

600mm

 

850mm

 

900mm

 

100kg

 

 

1.2

 

SITING

 

The

 

appliance

 

should

 

be

 

installed

 

on

 

a

 

firm,

 

level

 

floor

 

in

 

a

 

well

 

lit

 

and

 

draught

 

free

 

position.

 

The

 

unit

 

must

 

be

 

secured

 

to

 

floor

 

using

 

the

 

holes

 

in

 

the

 

feet.The

 

installation

 

of

 

the

 

appliance

 

must

 

be

 

made

 

in

 

accordance

 

with

 

local

 

and/or

 

national

 

regulations

 

as

 

listed

 

on

 

the

 

cover

 

of

 

this

 

manual,

 

and

 

a

 

competent

 

installer

 

must

 

be

 

employed.

 

The

 

unit

 

may

 

be

 

installed

 

against

 

both

 

side

 

and

 

rear

 

walls.

 

1.3

 

ELECTRICAL

 

SUPPLY

 

The

 

fryers

 

are

 

for

 

use

 

on

 

A.C.

 

supplies

 

only,

 

and

 

the

 

terminals

 

are

 

normally

 

arranged

 

for

 

2

 

or

 

3

 

phase

 

operation.

 

If

 

single

 

phase

 

supply

 

is

 

specified,

 

the

 

appropriate

 

copper

 

bridging

 

plate

 

is

 

supplied

 

with

  

appliance.

 

It

 

is

 

important

 

that

 

connections

 

are

 

made

 

exactly

 

as

 

shown

 

in

 

the

 

following

 

diagram.Cable

 

entry

 

is

 

at

 

rear

 

RH

 

side

 

of

 

unit,

 

in

 

the

 

form

 

of

 

a

 

30mm

 

diameter

 

conduit

 

connection.

 

A

 

conduit

 

tube

 

extends

 

forward

 

into

 

control

 

compartment.

 

Access

 

to

 

this

 

area

 

is

 

gained

 

upon

 

removing

 

cover

 

behind

 

door.A

 

suitably

 

rated

 

isolating

 

switch

 

with

 

contact

    

separation

 

of

 

at

 

least

 

3

 

mm

 

in

 

all

 

poles

 

must

 

be

 

installed

 

and

 

wiring

 

executed

 

in

 

accordance

 

with

  

relevant

 

regulations

 

listed

 

on

 

front

 

cover

 

of

 

this

 

manual.

 

Note

 

When

 

a

 

unit

 

is

 

stored

 

for

 

a

 

long

 

period

 

prior

 

to

 

installation,

 

especially

 

in

 

damp

 

conditions,

 

insulation

 

resistance

 

of

 

elements

 

may

 

fall

 

to

 

an

 

unacceptable

 

level

 

(i.e.

 

above

 

2

).Should

 

this

 

occur,

 

it

 

is

 

recommended

 

that

 

the

 

elements

 

be

 

switched

 

on

 

for

 

an

 

hour

 

and

 

then

 

be

 

allowed

 

to

 

cool.

 

This

 

process

 

being

 

repeated

 

as

 

necessary

 

to

 

restore

 

the

 

required

 

insulation

 

resistance.

 

Warning

 

This

 

Appliance

 

must

 

be

 

earthed.

 

Electrical

 

loadings

 

are

 

as

 

stated

 

on

 

unit

 

data

 

plate.

 

 

 