22
FAULT FINDING
FAULT
POSSIBLE CAUSES
REMEDY
Red and Amber neon not
lighting.
No power from the supply.
Restore supply.
Blown fuse.
Replace fuse.
Faulty mains supply cord.
Replace supply cord.
Faulty Neons.
Replace Neons.
Amber neon not lighting but
Red neon is on.
Safety Thermostat tripped or
faulty.
Reset Thermostat. If faulty,
replace.
Operating Thermostat.
Check connections. If faulty,
replace.
Amber Neon.
Contactors.
Slow/Poor heating.
Operating Thermostat out of
calibration.
Replace Operating
thermostat.
Faulty Elements or
connections.
Check each connection to
the three elements. If any of
them are faulty, replace.
SPARE PARTS
MAIN SPARES LIST
PART NAME
SPARES NUMBER
Red Neon
730962010
Amber Neon
730962040
Operating Thermostat
732150020
On / Off Switch
732910481
Safety Thermostat
732150006
Tilt Switch
531750540
Contactor
734310440
Element
732150001
1A anti surge fuse
535420014
When ordering spare parts please quote the following;
Appliance type
Serial number
This information will be found on data plate attached to base plate.