Falcon Foodservice Equipment Dominator Plus E3800DX User, Installation And Servicing Instructions Download Page 19

19

 

 

To replace the elements, first the element box must be removed as shown.  

 

 

When replacing the bottom two elements, the thermostat tube must be removed as well. They 
are all attached by hex nuts. 

 

 

When replacing the Elements, ensure it is secured tightly to the pan base. 
Ensure Thermostat Tube is attached tightly to the Elements.  

 

Summary of Contents for Dominator Plus E3800DX

Page 1: ...USERS INSTALLATION AND SERVICING INSTRUCTIONS ELECTRIC BRATT PAN E3800DX T100839 Rev 13 DATE PURCHASED MODEL NUMBER SERIAL NUMBER DEALER SERVICE PROVIDER...

Page 2: ...placement parts in a safe manner via a licensed waste handler Appliances are designed to be dismantled easily and recycling of all material is encouraged whenever practicable Falcon Foodservice Equipm...

Page 3: ...sconnector must meet the specification requirements of IEC 60947 Your attention is drawn to BS 7671 2018 Guidance Note 8 8 13 Other locations of increased risk It is recognized that there may be locat...

Page 4: ...del Number covered in this group of products 9 Technical Data 9 DIMENSIONS ELECTRICAL CONNECTION LOCATIONS 9 INSTALLATION 10 Unpacking 10 Siting Clearances 10 Electric Supply Connection 11 Water Suppl...

Page 5: ...and National Regulations in force at the time of installation Particular attention MUST be paid to BS7671 IEE Wiring Regulations Electricity at Work Regulations Health And Safety At Work Act Fire Pre...

Page 6: ...Controls OFF Position Variable temperature setting 100 C 300 C Turn handle to lift pan up and down Turn tap to turn water ON and OFF Indicates that the heating element is ON Indicates when mains elect...

Page 7: ...When the desired temperature is reached the Amber neon will go OFF 5 If cooking a liquid based food ensure it does not go over the MAX mark as shown below 6 Turn ON the water tap to top up if necessar...

Page 8: ...CAUTION Failure due to lack of proper cleaning is not covered by warranty BEFORE ANY CLEANING IS UNDERTAKEN ENSURE ISOLATING COCK IS TURNED OFF AND CANNOT BE INADVERTENTLY TURNED ON WARNING DO NOT AT...

Page 9: ...in this group of products E3800 800mm wide manual lift electric Bratt Pan Technical Data DIMENSIONS ELECTRICAL CONNECTION LOCATIONS E3800 7 7 L1 11 2 L2 11 2 L3 11 2 TECHNICAL DATA TABLE A MODEL NUMB...

Page 10: ...Fit Lid handle using fixings supplied and locate water inlet pipe in position in the rear flue at the left hand side Siting Clearances CAUTION If suiting the necessary clearances to any combustible w...

Page 11: ...st 3mm in all poles must be installed and wiring executed in accordance with relevant regulations Access to mains terminal block is gained by removing the control panel Water Supply Connection to the...

Page 12: ...RE AWARE OF THE MAINS ISOLATING SWITCH LOCATION PLEASE FILL OUT THE INFORMATION TABLE ON THE FRONT COVER AFTER COMMISSIONING SERVICING BEFORE ATTEMPTING ANY SERVICING ENSURE ISOLATING COCK IS TURNED O...

Page 13: ...res to be removed denotes a flat head screw requires to be removes denotes a nut or a hex head bolt requires to be removed REMOVAL OF FRONT FASCIA ACCESS TO ELECTRICS BOX To gain access to the electri...

Page 14: ...14...

Page 15: ...15 7 When removing the front fascia care should be taken not to damage the neon cables NEONS Neons are attached to the front fascia To replace them remove the connections and the nut...

Page 16: ...replace remove the clip that secures the thermostat capillary Pull out thermostat phial then remove the two screws on the cover of the electrics box 1 2 When replacing the thermostat phial back into t...

Page 17: ...of the box to reset To replace remove the same clip that s shown in the operating thermostat Pull out phial then remove the two screws When replacing the thermostat phial back into the hole ensure th...

Page 18: ...d in the electrics box To replace lever it out by using a flat headed screwdriver ELEMENTS Lift Pan fully up to get access to the Element Box To gain access to just the element connections remove the...

Page 19: ...ved as shown When replacing the bottom two elements the thermostat tube must be removed as well They are all attached by hex nuts When replacing the Elements ensure it is secured tightly to the pan ba...

Page 20: ...20 Wiring Diagram 400V 3N Appliance...

Page 21: ...21 Circuit Diagram...

Page 22: ...ow Poor heating Operating Thermostat out of calibration Replace Operating thermostat Faulty Elements or connections Check each connection to the three elements If any of them are faulty replace SPARE...

Page 23: ...vice calls to equipment under warranty will be carried out in accordance with the conditions of sale Warranty calls can be made between 8 30 am and 5 00 pm weekdays only To ensure your warranty enquir...

Reviews: