Fault
Appliance does not
work.
Vacuum cleaning is
unsatisfactory.
Appliance runs
unusually loud.
Possible cause
Plug is not inserted or the
appliance is not switched on.
Power outlet does not carry
any power.
Power cord is damaged.
Dust bag is full.
Filter is dirty or clogged.
Nozzle, telescopic suction tube
or suction hose are clogged
up.
Suction regulator is open.
The power setting does not
suit the flooring.
The attached nozzle does not
fit the flooring.
The “carpet/hard floor” switch
is in the wrong position for the
particular type of floor.
Sucked-in particles have
become jammed.
Solution
Insert the plug into a mains socket
and switch on the appliance.
Test the appliance at another
socket which you are sure carries
current.
Have the power cord replaced by
an authorised Fakir service centre.
Change dust bag.
Clean or change the corresponding
filter.
Eliminate clogging. If necessary,
use a wooden stick (e.g. a
broomstick) to do this.
Close suction regulator.
Set the power to the setting
suggested for the flooring.
Attach the correct nozzle.
Set the “carpet/hard floor” switch to
the correct position for the type of
floor.
Remove particles. If necessary,
use a long wooden stick (e.g. a
broomstick).