1. Loosen the Cope Stud before rotating the PIR sensor
2. Adjust the detection area by rotating the PIR sensor.
3. Adjusting the duration time: Turning the TIME KNOB
from (-) to (+) will increase the duration time (
refer to Fig.6
)
4. Adjusting the LUX control level: ( ) position denotes that
the PIR can switch the floodlight on during daylight hours or
at night. ( ) position denotes that the PIR can only switch
the floodlight on at night. (
refer to Fig.6
)
5. Adjusting the sensitivity: Turning the SENS KNOB from (-) to (+)
will increase the sensitivity of the detector. (
refer to Fig.6
)
6. Walk Test: The walk test will help you determine and adjust
the detection area of your PIR. To carry out this test place the
LUX control to the day position and the TIME control to
minimum (-). Once the PIR sensor receives a valid trigger
signal (such as the movement of a human body) within its
detection area, the floodlight will be turned on for the pre-set
period of time. You may fine-tune the detection area by
adjusting the angle, position and sensitivity of the PRI, to that
suitable for the position of the floodlight.
FAITHFULL TOOLS
Long Reach, Galleon Boulevard,
Crossways Business Park, Dartford,
Kent, DA2 6QE, United Kingdom
E-mail: [email protected]
www.faithfulltools.com
ENVIRONMENTAL PROTECTION
Waste electrical products should not
be thrown away with household waste.
Please recycle where facilities exist.
Check with your local authority or
retailer for recycling advice.
The Faithfull Tools Catalogue
features approximately 2,600 products.
Ask your local Faithfull stockist for a
copy or write to the address below.
FIG. 6
Disposal
This product, accessories and packaging should be sorted for
environment-friendly recycling.
Model:
FPP SL150PIR
Voltage:
220-240VAC 50Hz
Bulb:
Max. 150Watt, R7s 78mm tungsten halogen lamp
Waterproof: IP44
Tempered Glass(LxWxT): 133mm x 93mm x 4mm
Unit Dimension(LxWxH): 140mm x 115mm x 200mm
Technical Data
2) Operating Instructions for the (PIR) Movement Detector
1. THE FLOODLIGHT MUST BE EARTHED
2. BEFORE TOUCHING THE FLOODLIGHT, PLEASE SWITCH OFF AND ALLOW IT TO COOL.
3. IN THE EVENT OF DAMAGE OF THE SAFETY SHIELD, MUST BE REPLACED IMMEDIATELY WITH TEMPERED GLASS.
4. ALWAYS ENSURE THAT THE MAINS SUPPLY IS SWITCH OFF BEFORE FITTING A REPLACEMENT HALOGEN TUBE.
FIG. 5
IMPORTANT: Never attempt to remove the PIR lens cover, as this will damage the PIR
and render the guarantee invalid.
Warning
SENS
TIME
LUX
SENS
TIME
LUX
Cope
Stud
The following adjustments may be made to this unit.
1. To select the detection area (area of movement), adjust the angle of
the PIR. (
see Fig.5
)
2. You can select the scanning field of PIR by adjusting it’s position on
the swivel joint. (
see Fig.6
)
3. You can adjust the time that the lamp illuminates from 10 5 seconds
to 4 1 minutes).
4. The ( ) position indicates that the PIR will function both at night and during
daylight, the ( ) position indicates that the PIR will only work at night.
+-
+-
2.5M
5M 10M 12M
180
o
Detection Angle
3) Setting Up and Adjusting the PIR