- Press the
+ (up) and - (down) button
together for 2~3 seconds to enter the settings.
- Press the
setting button
to change options, jumping character means the option being set.
- Hold the
setting button 2~3 seconds
to finish and quit the setting.
- Press
the + (up) or - (down) button
to change setting objects or values.
When an error is detected, the display LCD will show an error code.
The error codes range from:
- Error 01: Controller overheating
- Error 07: Motor phase lost
- Error 22: Throttle error
- Error 24: Motor hall error
- Error 30: Controller communication error
09
Error Code Definition
Enter the setting
Setup Details
No Name
Status
P01
P02
P03
P04
P05
P06
P07
P08
P09
Unit
Backlight illumination
Auto shutdown time
Wheel diameter
Speed Limiting
Pre-charging
Gear Range
Cruise Control
Password Setting
00-Metric System 01-British System Default: 00
Range:1-3 Default: 2
00-No shutdown Default:10 mins
Range adjustable, Default: 20F
Range Adjustable, Default: 32mph
Range:1-3, Default:1
Range: 0-3、1-3、0-5、1-5、0-7、1-7、0-9、1-9, Default:0-5
00-Auto Curise Off, 01-Auto Curise On, Default: 00
Option: 24V 36V 48V 52V 60V Default:48V
range: 2-9 default: 4
The password function is not enabled by default. You can change
the Psd-N into Psd-y to activate the function. The default password
is 1212 and it could be changed by yourself. You must remember the
password after your change it!. Default: N
Voltage rating
PAS sensitivity setting
P10
P11