background image

 

 

18 

 

 

Refer to the wiring diagram, the machine data plate and technical specifications 
for service size requirements. 

 

Check that the mains voltage corresponds to that indicated on the nameplate. 

 

The power-supply cord shall be Type S, SE, SO, SOO, ST, STO, or STOO (with 
or without W at the end). 

 

The  power  supply  cord  wire  size  must  be  suitable  for  the  rated  current  of  the 
machine (amperage load). Use copper conductors only. 

 

The  appliance  must  be  grounded  using  the  ground  connection  of  the  terminal 
block of the appliance. 

 

An all phase Circuit Breaker must be installed near to the appliance between the 
power  supply  and  the  appliance  in  accordance  to  required  consumption 
guidelines. Switch the circuit breaker to “OFF” when servicing the appliance. It is 
recommended that it has lockout-tagout capabilities. The manufacturer will not be 
held liable for damage originated by failure to observe this requirement. 

 

A  suitable  safety  switch  /  Residual  current  device  must  be  installed  near  the 
appliance between the power supply and the appliance. The manufacturer will not 
be held liable for damage originated by failure to observe this requirement.  

 

If any faults are observed  during the installation, the  supplier should be notified 
immediately. 

When  a  number  of  appliances  are  installed  in  line,  they  should  all  be  ground  bonded  at  the  point 
provided for that purpose. 

To access the connection strip when a permanent connection needs to be made, release the cover of 
the  machine’s  front  (see  chapter  2.  General  measurements  and  connections).  The  power  cable  is 
connected to the connection strip. It is also possible to change the machine configuration here. 

 

The manufacturer will not be held liable for any personal or material damage to the 
machine  resulting  from  incorrect  installation  or  failure  to  comply  with  the 
manufacturer’s specifications. 

 

 

It  is  the  personal  responsibility  and  obligation  of  the  customer  to  contact  a 
qualified electrician to assure that the electrical installation is adequate. 

 

8.4

 

Hydraulic connection 

The new hoses supplied with the appliance should be used (do not reuse old hoses). 

Before connecting the machine to the water supply, the water quality should be tested.

 

Recommended water quality: 

pH: 

6.5 to 7.5 

 

Alkalinity: 

Less than 50 ppm (mg/L) 

Free Chlorine: 

Less than 0.2 ppm (mg/L) 

 

Total Dissolved Solids (TDS): 

Less than 60 ppm 

Chlorides: 

Less than 30 ppm (mg/L) 

 

Sulfates:   

Less than 40 ppm 

Hardness: 

Less than 3 gpg (52 ppm) 

 

Iron:   

Less than 0.1 ppm 

Conductivity: 

400 

– 1.000 µS/cm 

 

Copper:  

Less than 0.05 ppm 

Silica: 

Less than 12 ppm (mg/L) 

 

Manganese: 

Less than 0.05 ppm 

Water installation is carried out as shown in 

Fig. 1:

 

 

S

 

 SHUT-OFF COCK 

F

 

 FILTER 

H

 

 WATER HOSE 

E

 

 WATER VALVE 

Fig. 1

Direct connection of water input hose. 

 

Summary of Contents for W Series

Page 1: ...AL INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE W MODELS MOD COP 174 W COP 504 W CO 502 W CO 500 W CO 402 W CO 400 W CODE 12220401 REV 05 2021 Hood type Dishwasher Undercounter Dishwasher Glasswa...

Page 2: ...NT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT Model P...

Page 3: ...PPM Equipment failure due to inadequate water supply is not covered by this Warranty Proper Maintenance and Operation The Equipment must be properly maintained and operated in accordance with Fagor s...

Page 4: ...ic rinse aid dispenser COP MODELS 21 8 8 Detergent dispenser 22 8 9 Recycling 23 9 USE AND MAINTENANCE INSTRUCTIONS 24 9 1 Operation 24 9 1 1 Control panel symbols 24 9 1 2 Switching on the machine 25...

Page 5: ...RAL MEASUREMENTS AND CONNECTIONS Hood type Dishwasher COP 174 W A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Connection Strip Inside Rinse aid inlet Detergent inlet Equipotent...

Page 6: ...6 Hood type Dishwasher COP 174 W HRS A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Connection Strip Inside Rinse aid inlet Detergent inlet Equipotential bond...

Page 7: ...Dishwasher CO 500 W CO 502 W COP 504 W Glasswasher CO 400 W CO 402 W A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Connection Strip Inside Rinse aid inlet Detergent inlet Equi...

Page 8: ...8 3 QUICK STARTUP GUIDES...

Page 9: ...9...

Page 10: ...10 4 ELECTRICAL DIAGRAM...

Page 11: ...11...

Page 12: ...4 Power On Light RT Tank Heating Element H5 Effi rinse Light S1 S2 S3 Program Cycle Push button HC Boiler temperature Display S4 ON OFF Push button HT Tank Temperature Display S5 Lack of salt switch K...

Page 13: ...ny other objects must not be washed in the machine If your machine breaks down please call the Technical Service Centre Unqualified or unauthorised personnel must NOT try to repair the machine Use of...

Page 14: ...WASH MIN TEMP HEATING ELEMENTS OPERATING CYCLE TIME s MODEL PUMP MOTOR WASH RINSE WASH TANK kW BOILER kW WASH DWELL RINSE HRS TOTAL COP 174W HRS 1 hp 156 F 180 F 4 9 3 25 13 1 8 7 39 59 104 584 5 11...

Page 15: ...ll Power 3Ph 240V 17 35 6 74 2 72 0 64 3 05 6 10 CO 502W 208 240V 208V 24 34 5 06 2 36 0 48 2 29 4 58 COP 504W 60Hz 220V 25 74 5 66 2 50 0 54 2 56 5 12 Full Power 1Ph 240V 28 08 6 74 2 72 0 64 3 05 6...

Page 16: ...55 AWG 6 MCA 54 MOP 60 CO 502W COP 504W 208 240V 60Hz 3Ph 208 240V 60Hz 1Ph 208 240V 60Hz 1Ph 208 240V 60Hz 1Ph BRIDGE Boiler Full Power Boiler Full Power Boiler 2 3 Power Boiler Half Power AWG 12 MCA...

Page 17: ...d The machine should be moved using a fork lift truck or similar to avoid damage to the structure Transport the machine to the installation location and then remove packaging All the packaging can be...

Page 18: ...es are installed in line they should all be ground bonded at the point provided for that purpose To access the connection strip when a permanent connection needs to be made release the cover of the ma...

Page 19: ...est results except in hood type HRS models where the water inlet temperature should be between 41 F and 77 F in order for the HRS system to function properly Slowly turn on the water supply to the mac...

Page 20: ...ovide you visible mean that chemicals are being dispensed Operation This dispenser absorbs the rinse aid when it detects a loss in pressure during rinsing That is when the filling solenoid valve close...

Page 21: ...at optimum conditions it is requested to remove lime and corrosion deposits on a frequent basis A de liming solution should be available from your chemical supplier Read and follow all instructions on...

Page 22: ...h Temperature Low Suds Liquid Detergent Fagor doesn t recommend any specific brand name of chemicals Contact your local chemical distributor for questions concerning your chemical needs Installation t...

Page 23: ...All the packaging used around the machine can be recycled The correct disposal of these products will help to protect the environment For further information regarding the recycling of these products...

Page 24: ...able options 9 1 1 Control panel symbols CO 400W Glasswasher CO 500W Front Loading Dishwasher CO 402W Glasswasher CO 502W COP 504W Front Loading Dishwasher COP 174W COP 174W HRS Hood Type Dishwasher O...

Page 25: ...that in the event of the breakdown of any of the main thermostats the safety thermostats switch off the corresponding heating During the first heating of the day the boiler may reach a higher tempera...

Page 26: ...cycle The wash cycle selected by default is P2 in machines with more than one wash cycle button Each wash cycle corresponds to a wash time that should be selected according to the user requirements Wh...

Page 27: ...ng care not to burn yourself as the dishes are extremely hot 9 1 7 Drainage of the machine The dishwashers have two types of drainage gravity drainage or using a drainage pump which is optional 9 1 7...

Page 28: ...tableware inside the machine from being cleaned properly 9 1 9 Cleaning the machine at the end of the day At the end of the day the filters wash distributors rinse branches and other accessories must...

Page 29: ...your technical service to protect the machine against frosts 10 FAULTS ALARMS AND BREAKDOWNS The steps to be followed in the event of a fault or operating error are described below The possible cause...

Page 30: ...rinse aid Call technical service to adjust rinse aid dispenser Water too chalky Check water hardness Machine stops during operation Electrical installation overloaded Call technical service to modify...

Page 31: ...ting failure E6 TH E6 Tank Heating WARNING on display Draining error After 2 minutes with drain cycle the level of the tank has not dropped E7 DR E7 Drain Machine disabled The boiler does not fill Aft...