background image

 

 

30 

 

FAULT 

POSSIBLE CAUSE 

SOLUTION 

Unsatisfactory wash. 

Wash distributors 
obstructed. 

Clean distributors thoroughly. 

Shortage of detergent. 

Call the technical service to reset the dispenser. 

Dirty filters. 

Clean the filters thoroughly. 

Presence of foam. 

Unsuitable detergent. Call the technical service 
to supply correct detergent. 

Too much rinse aid. Call the technical service to 
reset the dispenser. 

Temperature of lower tub at 
50 

C / 122 

F. 

Thermostat faulty or incorrectly set. Call the 
technical service to repair it. 

Length of cycle too short for 
level of dirt on dishes. 

Select a longer cycle. 

Water too dirty. 

Drain the wash tub and fill with clean water. 

Dishes and 
kitchenware are not 
dry. 

There is no rinse aid 

Fill the rinse aid container. 

Rinse aid low. 

Call technical service to adjust dispenser. 

Dishes left inside 
dishwasher for too long. 

When the dishwasher finishes, remove the 
basket from the machine and allow to dry 
naturally. 

Rinse temperature lower 
than 80 

C / 176 

F. 

Call technical service to analyse problem. 

Scratches or stains on 
dishes. 

Too much rinse aid. 

Call technical service to adjust rinse aid 
dispenser. 

Water too chalky. 

Check water hardness. 

Machine stops during 
operation. 

Electrical installation 
overloaded. 

Call technical service to modify electrical 
installation. 

Machine protection has 
tripped. 

Reset safety device and if it trips again, call 
technical service. 

Machine stops and 
fills with water when it 
is washing. 

Pressure switch pipe 
blocked. 

Empty the tub and clean thoroughly. 

Pressure switch faulty. 

Call the technical service to replace it. 

Overflow incorrectly 
mounted. 

Mount overflow correctly. 

The machine does not 
start with the wash 
cycle. 

Hood/door is not closed 
properly. 

Close the hood/door correctly and if it is seen to 
re-open alone, call the technical services to 
adjust the tensioners. 

Hood/door micro switch 
faulty. 

Call the technical service to replace it. 

Machine does not 
drain completely. 

Machine not levelled 
correctly. 

Level the machine. In the event of doubt, please 
contact your technical service. 

Pressure switch faulty. 

Call the technical service to replace the 
pressure switch. 

 

 

NOTE: If a fault occurs and is not listed in the above table, please call the 
technical  service.  The  manufacturer  reserves  the  right  to  modify  the 
technical characteristics with prior warning. 

 

 

Summary of Contents for W Series

Page 1: ...AL INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE W MODELS MOD COP 174 W COP 504 W CO 502 W CO 500 W CO 402 W CO 400 W CODE 12220401 REV 05 2021 Hood type Dishwasher Undercounter Dishwasher Glasswa...

Page 2: ...NT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT Model P...

Page 3: ...PPM Equipment failure due to inadequate water supply is not covered by this Warranty Proper Maintenance and Operation The Equipment must be properly maintained and operated in accordance with Fagor s...

Page 4: ...ic rinse aid dispenser COP MODELS 21 8 8 Detergent dispenser 22 8 9 Recycling 23 9 USE AND MAINTENANCE INSTRUCTIONS 24 9 1 Operation 24 9 1 1 Control panel symbols 24 9 1 2 Switching on the machine 25...

Page 5: ...RAL MEASUREMENTS AND CONNECTIONS Hood type Dishwasher COP 174 W A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Connection Strip Inside Rinse aid inlet Detergent inlet Equipotent...

Page 6: ...6 Hood type Dishwasher COP 174 W HRS A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Connection Strip Inside Rinse aid inlet Detergent inlet Equipotential bond...

Page 7: ...Dishwasher CO 500 W CO 502 W COP 504 W Glasswasher CO 400 W CO 402 W A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Connection Strip Inside Rinse aid inlet Detergent inlet Equi...

Page 8: ...8 3 QUICK STARTUP GUIDES...

Page 9: ...9...

Page 10: ...10 4 ELECTRICAL DIAGRAM...

Page 11: ...11...

Page 12: ...4 Power On Light RT Tank Heating Element H5 Effi rinse Light S1 S2 S3 Program Cycle Push button HC Boiler temperature Display S4 ON OFF Push button HT Tank Temperature Display S5 Lack of salt switch K...

Page 13: ...ny other objects must not be washed in the machine If your machine breaks down please call the Technical Service Centre Unqualified or unauthorised personnel must NOT try to repair the machine Use of...

Page 14: ...WASH MIN TEMP HEATING ELEMENTS OPERATING CYCLE TIME s MODEL PUMP MOTOR WASH RINSE WASH TANK kW BOILER kW WASH DWELL RINSE HRS TOTAL COP 174W HRS 1 hp 156 F 180 F 4 9 3 25 13 1 8 7 39 59 104 584 5 11...

Page 15: ...ll Power 3Ph 240V 17 35 6 74 2 72 0 64 3 05 6 10 CO 502W 208 240V 208V 24 34 5 06 2 36 0 48 2 29 4 58 COP 504W 60Hz 220V 25 74 5 66 2 50 0 54 2 56 5 12 Full Power 1Ph 240V 28 08 6 74 2 72 0 64 3 05 6...

Page 16: ...55 AWG 6 MCA 54 MOP 60 CO 502W COP 504W 208 240V 60Hz 3Ph 208 240V 60Hz 1Ph 208 240V 60Hz 1Ph 208 240V 60Hz 1Ph BRIDGE Boiler Full Power Boiler Full Power Boiler 2 3 Power Boiler Half Power AWG 12 MCA...

Page 17: ...d The machine should be moved using a fork lift truck or similar to avoid damage to the structure Transport the machine to the installation location and then remove packaging All the packaging can be...

Page 18: ...es are installed in line they should all be ground bonded at the point provided for that purpose To access the connection strip when a permanent connection needs to be made release the cover of the ma...

Page 19: ...est results except in hood type HRS models where the water inlet temperature should be between 41 F and 77 F in order for the HRS system to function properly Slowly turn on the water supply to the mac...

Page 20: ...ovide you visible mean that chemicals are being dispensed Operation This dispenser absorbs the rinse aid when it detects a loss in pressure during rinsing That is when the filling solenoid valve close...

Page 21: ...at optimum conditions it is requested to remove lime and corrosion deposits on a frequent basis A de liming solution should be available from your chemical supplier Read and follow all instructions on...

Page 22: ...h Temperature Low Suds Liquid Detergent Fagor doesn t recommend any specific brand name of chemicals Contact your local chemical distributor for questions concerning your chemical needs Installation t...

Page 23: ...All the packaging used around the machine can be recycled The correct disposal of these products will help to protect the environment For further information regarding the recycling of these products...

Page 24: ...able options 9 1 1 Control panel symbols CO 400W Glasswasher CO 500W Front Loading Dishwasher CO 402W Glasswasher CO 502W COP 504W Front Loading Dishwasher COP 174W COP 174W HRS Hood Type Dishwasher O...

Page 25: ...that in the event of the breakdown of any of the main thermostats the safety thermostats switch off the corresponding heating During the first heating of the day the boiler may reach a higher tempera...

Page 26: ...cycle The wash cycle selected by default is P2 in machines with more than one wash cycle button Each wash cycle corresponds to a wash time that should be selected according to the user requirements Wh...

Page 27: ...ng care not to burn yourself as the dishes are extremely hot 9 1 7 Drainage of the machine The dishwashers have two types of drainage gravity drainage or using a drainage pump which is optional 9 1 7...

Page 28: ...tableware inside the machine from being cleaned properly 9 1 9 Cleaning the machine at the end of the day At the end of the day the filters wash distributors rinse branches and other accessories must...

Page 29: ...your technical service to protect the machine against frosts 10 FAULTS ALARMS AND BREAKDOWNS The steps to be followed in the event of a fault or operating error are described below The possible cause...

Page 30: ...rinse aid Call technical service to adjust rinse aid dispenser Water too chalky Check water hardness Machine stops during operation Electrical installation overloaded Call technical service to modify...

Page 31: ...ting failure E6 TH E6 Tank Heating WARNING on display Draining error After 2 minutes with drain cycle the level of the tank has not dropped E7 DR E7 Drain Machine disabled The boiler does not fill Aft...

Page 32: ...Fagor Commercial Inc 13105 NW 47th Avenue Miami FL 33054 USA T 305 779 0170 Fax 305 779 0173 1 866 GO FAGOR www fagorcommercial com...

Reviews: