1.2 Turning the unit on and off

It turns on automatically when applying voltage or after pressing the on/off
key.

It shows 

Fagor dro

 or the corresponding error code. See the error table and

PAR11 for more options.

Turns the DRO on or off.

Precautions

Before disconnecting this unit from mains, press this key so it saves the
current position.

If the unit is turned off or there is a power outage, the DRO will try to save the
current position. If it does not have enough time to safe all the data, it will
display ERROR 2 when turned back on.

Summary of Contents for Innova 10i

Page 1: ...Fagor Automation S Coop 10i 20i 10i B 20i B Installation Operation Manual Manual code 14460055 Manual version 0703 Software version 4 xx...

Page 2: ...erations 10 2 5 1 Scaling factor 10 2 5 2 Part centering 10 3 DRO installation 11 3 1 Installation of the built in model 11 3 2 Rear panel 12 3 3 General technical characteristics 13 3 4 Connections 1...

Page 3: ...key This key toggles the display format for the rotary axis between decimal degrees and Degrees Minutes Seconds To get into and out of home search mode To access the special function HOLD To select th...

Page 4: ...e corresponding error code See the error table and PAR11 for more options Turns the DRO on or off Precautions Before disconnecting this unit from mains press this key so it saves the current position...

Page 5: ...t of the axis diameter by pressing this key The led will turn on or off to indicate the double or actual reading respectively Notes This works in this way if bit 2 of installation parameter PAR04 radi...

Page 6: ...nt chosen in the feedback system linear or encoder Press this sequence to access the Home Search mode ABS In Absolute ABS when the ABS led is on it displays the distance from the present position of t...

Page 7: ...are using the same machine zero point home Fagor also offers encoders with distance coded reference marks every 20 40 or 100 mm When using these distance coded reference marks there is no need to move...

Page 8: ...The Y axis blinks waiting for the tool value to be entered It requests the tool length Enter this value pressing this keystroke sequence Note Since only the length of a tool may be stored when changi...

Page 9: ...e Move the axis until the display reads 23 000 C position and drill the hole Sets the X axis to zero See note Move the axis until the display reads 25 000 D position and drill the hole Note If install...

Page 10: ...tor 2 5 2 Part centering Note This feature is available when none of the axes have installation parameter PAR04 2 1 radius diameter commutable Part centering can be done as follows Set the dro in abso...

Page 11: ...ation Operation DRO installation 11 29 3 DRO installation 3 1 Installation of the built in model Dimensions of the enclosure hole for inserting the DRO Built in DRO insertion Bolt ISO 7380 M4 x 10 Ino...

Page 12: ...pin female connector for 1st axis feedback device X2 20i SUB D HD type 15 pin female connector for 2nd axis feedback device scale or encoder UL seal In order to comply with UL standards this unit mus...

Page 13: ...5 C and 45 C 41 F and 113 F The storage temperature inside the DRO enclosure must be 25 C and 70 C 13 F and 158 F Maximum relative humidity 95 non condensing at 45 C 113 F Front Panel Sealing IP54 DIN...

Page 14: ...splays will show Setup meaning that the feedback is not set up yet 3 5 2 Operating mode Move the axis to the origin or zero point and press the axis key The display shows START Move the axis in the po...

Page 15: ...onfigure it for a particular application The way these parameters are displayed depends on whether they are general or particular for each axis If it affects the axes the parameter number PAR appears...

Page 16: ...elect axis Press this key to save the displayed value Press this key to cancel the modification Move through parameters Press the ENTER key to go on to the next parameter or Press this key to return t...

Page 17: ...nits Linear axis 0 mm 1 inches Rotary axis 0 degrees 1 seconds Note These units refer to feedback pulses not to the position display 4 Type of axis 0 Linear 1 Rotary 3 Not being used at this time 2 No...

Page 18: ...e p Pulses per turn of the encoder P Leadscrew pitch in mm turn R Resolution in mm pulse F Multiplying factor to be applied PAR03 External multiplying factor when using distance coded reference marks...

Page 19: ...g of this parameter will be ignored PAR07 Combine the reading of an axis Independent for each axis It indicates the number of the axis to be added 0 means none 1 X axis 2 Y Z With the negative sign th...

Page 20: ...eference point with respect to the reference zero of the scale independent for each axis Usually the machine reference zero reference mark of the linear encoder does not coincide with the absolute zer...

Page 21: ...r on If PAR08 bit 2 1 when the axis exceeds the travel distance between both parameters the relevant display starts blinking until it is positioned within these limits PAR14 Binary type home search se...

Page 22: ...until they are homed To use this compensation it is recommended to set PAR 14 so as to force a mandatory home search on power up The compensation point must have at least one point with no error erro...

Page 23: ...ny key or moving any of the axes turns the displays back on 2 1 Apply hysteresis onto the 2nd and 1st axis respectively PAR25 Hysteresis distance desired to avoid the flickering of the displayed posit...

Page 24: ...trical equipment of the machines ELECTROMAGNETIC COMPATIBILITY EN 61000 6 4 Emission EN 55011 Radiated Class A Group 1 EN 55011 Conducted Class A Group 1 EN 61000 3 2 Harmonics EN 61000 3 3 Flickers E...

Page 25: ...er to avoid electrical discharges and fire hazards do not apply electrical voltage outside the range indicated in chapter 2 of this manual Ground connection In order to avoid electrical discharges con...

Page 26: ...as Powerful loads connected to the same AC power line as this equipment Nearby portable transmitters Radio telephones Ham radio transmitters Nearby radio TC transmitters Nearby arc welding machines N...

Page 27: ...ce and has been manipulated by personnel authorized by FAGOR If once the service call or repair has been completed the cause of the failure is not to be blamed the FAGOR product the customer must cove...

Page 28: ...d outlets are as they should be If there are OK disconnect the feedback connectors one by one If the dro comes on it means a feedback failure If the fault persists get in touch with Fagor Automation s...

Page 29: ...amage the materials the equipment is made with Do not use high pressure compressed air to clean the item as this could give rise to an accumulation of charges which in turn lead to electrostatic disch...

Reviews: