For
Customer
Service: Call 1
‐
866
‐
GO FAGOR
FAGOR
–
BAR
EQUIPMENT:
Operations
and
Service
Manual
/
Rev.
April
2013
Page
7
3.8
DIVIDER
INSTALLATION
1)
Hook
the
dividers
to
their
proper
place
so
you
have
division
within
your
cabinet.
4 OPERATION
Verify
thermostat
is
in
the
OFF
position
prior
to
connecting
the
unit
to
its
power
source.
Failure
to
do
so
could
lead
to
electrical
failures.
Keep
in
mind
the
evaporator
fans
and
lights
will
still
have
power
while
the
thermostat
in
the
OFF
position.
Connect
unit
to
power
supply.
Temperature
controller
(inside
the
cabinet)
goes
from
0
(OFF
Position)
to
7
(Coolest
Position).
Set
control
at
position
5
for
temperature
average
of
35ºF.
4.1
DEFROST
The unit will not require defrosting if the door is only opened for a minimum time. Defrosting should
be done when the box is empty and periodically. To do this unplug the unit and leave the door open
for fifteen minutes. Defrost water will accumulate in a pan under the evaporator and will
drain to a plastic container in the storage area under the unit.
Do not use a pick, knife, etc., to pry ice from evaporator as this could puncture evaporator or damage
the finish.
4.2
TROUBLESHOOTING
Sometimes,
working
failures
are
due
to
simple
causes
which
can
be
solved
by
the
user.
Before
asking
for
the
help
of
a
qualified
technician,
you
have
to
do
some
verification.
These
failures
are
not
covered
by
the
warranty:
1.
Refrigeration
doesn´t
work.
a.
Check
the
unit
is
still
connected
to
power
supply.
2.
Refrigerator
doesn’t
reach
temperature.
a.
Check
the
thermostat
is
not
in
OFF
position.
b.
Check
the
thermostat
is
at
position
5
or
higher.
c.
Check
the
unit
is
not
on
defrost
cycle.
d.
Check
gasket
is
in
good
condition
and
door
is
sealed.
e.
Check
fan
is
moving.
Open
the
door
press
and
hold
door
switch
for
verification.
f.
Don’t
put
any
food
inside
until
unit
is
at
temperature.
g.
Be
sure
castors
or
legs
were
installed.
3.
There
is
water
under
the
refrigerator.
a.
Check
the
drain
pipe
is
over
the
pan.
b.
Check
cabinet
is
level.
WARNING:
Machine
and
compressor
warranties
are
void
if
failure
is
due
to
improper
electrical
installation.