EN
34
4.
INSTALLATION INSTRUCTIONS
The positioning and installation, and all repairs or modifications,
should always be carried out by an AUTHORISED TECHNICIAN,
in accordance with the applicable legislation of the country.
The installation, incorrect adjustment, inappropriate maintenance or use of
the appliance may cause material damages and injuries.
4.1
Removal of packaging
Remove packaging from the machine and check for damage during transportation. If any damage is
observed, immediately notify the supplier and the transport company. In the event of doubt, do not
use the machine until the problem has been assessed.
Packaging (plast
ic, expanded polyurethane, staples, etc…) must not be left in the
reach of children, they are a potential hazard.
The machine should be moved using a fork-lift truck or similar to avoid damage to the structure.
Transport the machine to the installation location and then remove packaging.
All the packaging can be recycled. Dispose of packaging correctly.
4.2
Positioning and levelling
This appliance has adjustable feet. This is done by
turning the leveling stands to the desire height. For
optimum operation, it is essential that the machine is
correctly levelled. The flooring on which the machine
is to be installed must be able to bear the full weight
of the machine.
Inspect final location of the machine prior to installation to prevent
damage during use.
4.3
Electrical connection
An AUTHORISED TECHNICIAN should always carry out the appliance’s electrical connection.
The legal standards in force in each country regarding connection to the mains should be taken into
account.
Check that the mains voltage corresponds to that indicated on the nameplate.
The electric cable should be flexible, with an oil-proof covering, and it should not weigh
less than the cable in an ordinary sleeve made of standard polychloroprene or an
equivalent synthetic elastomer (H05RN-F).
The cross-section of the power cable must be suitable for the rated current of the
machine.
An easily accessible switch device should be installed next to the appliance for all the
phases, with a minimum gap of 3 mm between contacts. This switch should be used to
disconnect the appliance during installation, repair, cleaning and maintenance work. The
switch should have fuses suitable for use with the rated current (A) of the machine.
Alternatively, a suitable magneto-thermal switch may be used.
The appliance must be earthed using a differential protector. The manufacturer will not be
held liable for damage originated by failure to observe this requirement.
If any faults are observed during the installation, the supplier should be notified immediately.
To access the connection strip, release the cover of the machine
’s rear in the undercounter
dishwhasers and on the left lower side of the hood type dishwhasers. The power cable is connected
to the connection strip. It is also possible to change the machine configuration here.
Summary of Contents for EVO CONCEPT CO-502
Page 67: ......