Description of operation
t e c h n i c a l
18
3.6.3.- Imbalance Detection
DETECTION LEVEL WHEN WASHING
650 gr.
DETECTION LEVEL FOR LOW SPIN
750 gr.
DETECTION LEVEL FOR HIGH SPIN
1520 gr.
Note:
These data are for a belt tension of 120 Hz and a SELNI motor
Function in the stop programme end
While PN is kept off
(empty)
Door lock OFF & Pump OFF.
Power failure: It is ready to start a new programme
(pause status).
It is in PAUSE status.
When Start is pressed: restarts a new programme
While PN is kept on
(full)
Door lock OFF & Pump in cycles:
(1 minute On , 1 minute OFF)
In case of overflow, the first pump cycle is:
(6 minutes On , 1 minute OFF)
Power failure: stays in the same situation.
It is always in START status.
When Start is pressed: stays in the same situation.
Will show fault F2 while this condition exists.
Memory function for power cuts
Maintains programme memory for at least 2 hours.
When spinning, the step times are always reset
Changes in the programme selector
A programme change means that the programme will start again from the starting
position.