background image

 

18 

Attention!

 

The chimney is predisposed for installation of the filter 
Version.  
In certain models where it is required to use the cooker hood 
in the suction version then it is possible to overturn the upper 
section of the chimney and insert it inside the lower section of 
the chimney so that the air-exit perforations are not visible. 
The chimneys in which this operation is possible are 
recognizable by their bracket fixing points 

which are 

repeated also in the lower side of the upper section of the 
chimney (see installation sequence 

20a-20b

).  

Attention! 

for all pre-assembled models:  

the mounting operations 

“1, 2, 3”

 should not be taken into 

consideration, for installation begin at operation 

“4”

.  

 
1. 

  Rest the suction unit on a flat surface and thread the 

lower part of the hood onto it (consult the figure 
corresponding to the model in possession - 

Fig. 1C/8C - 

1D/8D - 1I/8I - 1E/8E - 1F/8F - 1G/8G - 1H/8H - 1R/8R - 
1N-1O-1P

)

.

 

2. 

  Make all the electrical connections between the two parts 

(Fig. 9)

3. 

  Permanently fix the cooker hood to the suction group with 

the screws (consult the figure corresponding to the model 
in possession - 

Fig. 1C/8C - 1D/8D - 1I/8I - 1E/8E - 

1F/8F - 1G/8G - 1H/8H - 1R/8R - 1N-1O-1P

)

.

 

4. 

  Using a pencil, draw a line on the wall, extending up to the 

ceiling, to mark the centre.  This will facilitate installation 

(Fig. 10)

5. 

  Rest the drilling template against the wall: the vertical 

centre line printed on the drilling template must 
correspond to the centre line drawn on the wall, and the 
bottom edge of the drilling template must correspond to 
the bottom edge of the hood: bear in mind that, when 
installation is complete, the underside of the hood must 
be at least 50 cm above the cooker top in the case of 
electric cookers, and at least 65 cm above the cooker top 
in the case of gas or mixed cookers. 

6.

   Place the lower support bracket on the perforation 

diagram making it coincide with the traced triangle, mark 
the two external holes and perforate.  Remove the 
perforation diagram, insert two wall-dowels and fix the 
support bracket of the hood with two 5x45 mm screws  

(Fig. 10)

 

Attention: only the models illustrated in Fig. 1Q/10Q:

 

 

Fix the central bracket with two screws and wall-dowels 
above the lower bracket (see perforation diagram for 
positioning the holes).   

7.

  If supplied dismantled, fix the hooks to the side of the 

aspiration group with two screws (

fig. 10a

). Hang the 

hood onto the lower bracket.  

8. 

  Adjust the distance of the hood from the wall. 

9.

   Adjust the horizontal position of the hood. 

10. 

  Using a pencil mark the cooker hood permanent drill hole 

inside the suction group (1 or 2 fixing points are 
necessary for permanent mounting) 

(Fig. 11)

.   

11.

 Remove the hood from the lower bracket. 

12.  

Drill at the point marked (Ø8mm) 

(Fig. 12)

13. 

Insert 1 or 2 wall screw anchors according to requirement. 

14.

  Apply the flues support bracket „

G

“ to the wall adherent to 

the ceiling, use the flues support bracket as a perforation 
diagram (if present, the small slot on the support must 
coincide  with the line drawn previously on the wall)   and 
mark two holes with a pencil.   Make the holes (Ø8mm), 
and insert 2 dowels 

(Fig. 13)

15.

  Fix the chimney support bracket to the wall using two 

5x45mm screws. 

16.

   Hook the hood onto the bottom bracket. 

17.

  Fix the hood into its final position on the wall  

(ABSOLUTELY ESSENTIAL)

 

(Fig. 14)

18.

   Connect a pipe (pipe and pipe clamps not provided, to be 

purchased separately) for discharge of fumes to the 
connection ring located over the suction motor unit. 

 

If the hood is to be used in ducting version, the other end 
of the pipe must be connected to a device expelling the 
fumes to the outside.  If the hood is to be used in filter 
version, then fix the deflector 

F

 to the chimney support 

bracket 

G

  and connect the other extremity of the pipe to 

the connection ring placed on the deflector 

F (Fig.13-15)

.  

19.

 Connect the electricity. 

 

 

Attention: only the models illustrated in Fig. 1Q:

 

 

Continue from the installation sequence number 23. 

20.

  Apply the chimney stacks and fasten them at the top to 

the chimney support 

„G“

 (

20b

) using 2 screws (

20a

(Fig. 

16)

 

Only for model with optical fibers point lighting (Fig. 
1G):

 

  Check that the chimneys may be removed to permit 

access to the optical fibers lamp housing area.  

 

Only for the model with control panel on chimney flue 

(Fig. 1L- 17):

 

  Insert the command plate from the motor group through 

the chimney flue slit from the inside towards the outside 

(20c)

. Carry out the connection of the control panel to the 

command plate.  

 

Attention! The terminal pivot on the plate MUST 

correspond to the drill hole on the connection block 
situated at the back of the control panel.  

 

21. 

 Slide the bottom section of the chimney down until it 

completely covers the suction unit and slots into the 
housing provided on top of the hood (

Fig. 18)

22. 

 Fix the lower section  of the chimney with two screws 

(only for the model in 

Fig.

 

1H/19H-1J/19J-1L/19L-

1M/19M-1N/19N-1O/19O-1P/19P

). 

23.  Only the models illustrated in Fig. 1Q:

 

 

•  Put the flues unit on the suction unit.  

 

  Connect the electricity between the two parts 

(Fig. 9)

 

•  Fix the flue units definitively to the suction unit with the  

screws (consult the figure corresponding to the model in 
possession)  

(Fig. 8Q)

 

Attention! Check that the lower section of the flue fits 
onto the central bracket 

 (Fig. 20)

  •  Fix the upper section of the flue units to the flues 

support bracket with two screws 

(Fig. 16)

Remount the carbon filter frame and the fat/s filter/s and check 
the perfect functioning of the hood. 

Summary of Contents for 5CFB-90X

Page 1: ...5CFB 90X and 5CFB 60X WALL CANOPY 5CFB 5CFB 90X and 5CFB 90X and 5CFB 60X 60X WALL CANOPY WALL CANOPY Installation and Operation Manual ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ... category III conditions in accordance with the wiring rules Attention substituting the supply cable must be carried out by the authorised technical assistance service Mounting Expansion wall plugs are provided to secure the hood to most types of walls ceilings However a qualified technician must verify suitability of the materials in accordance with the type of wall ceiling The wall ceiling must ...

Page 11: ...nent mounting Fig 11 11 Remove the hood from the lower bracket 12 Drill at the point marked Ø8mm Fig 12 13 Insert 1 or 2 wall screw anchors according to requirement 14 Apply the flues support bracket G to the wall adherent to the ceiling use the flues support bracket as a perforation diagram if present the small slot on the support must coincide with the line drawn previously on the wall and mark ...

Page 12: ... cleaned press button 1 for about 3 seconds until you hear the acoustic signal beep the LED 4 will now stop flashing 5 Speed 3 LED and active carbon filter saturation LED in this latter case the LED will flash See instructions on active carbon filter replacement Once you have replaced the charcoal filter press button 1 for about 3 seconds until you hear the acoustic signal beep LED 5 will now stop...

Page 13: ... more before contacting the Technical Assistance Service Warning Always press the fan off button A before disconnecting the hood from the mains supply Functioning Model with display A B C D E F A Lighting on off B Fan off Stand by C Timer for selected speed visualizes the speed selected and flashing LED on the lower side of the display This knob permits the operation of the cooker hood for a estab...

Page 14: ... seconds A beep signals each time the operation is completed Enabling the carbon filter signal the hood is enabled only for the fats filter signal To enable the carbon filter signal hood in Off press keys T2 and T4 for 3 seconds The flashing of Leds 1 and 2 signals the completion of the setting To disenable the carbon filter signal repeat this operation again always with the hood in Off A beep sig...

Page 15: ... tool 2 Replace the damaged light bulb Only use halogen bulbs of 20W max G4 making sure you do not touch them with your hands 3 Close the lamp cover it will snap shut For models shown in Fig 1J Fig 4J 1 Use a small screwdriver as a lever on the borders of the lamp in order to remove the lightbulb 2 Unthread the connector a 3 Slide out the lightbulb to be replaced and replace with a new 12V 20W 30 ...

Page 16: ...ty measures to adopt for discharging fumes are concerned The hood is to be cleaned frequently both internally and externally Failure to observe the regulations about cleaning the hood and substituting and cleaning the filters can lead to the risk of fire Any responsibility is declined for possible inconveniences damage or fire caused to the apparatus deriving from failure to observe the instructio...

Reviews: