fafnir VAPORIX Manual Download Page 9

VAPORIX Service Dongle and VAPORIX Diagnostics

Page 9/19

4.3

Testing the shutdown of the dispenser point
If you want to test the triggering of an alarm and the shutdown in normal
operation:

1. Turn coding switch to position "1" for dispenser side A or to "2" for dispenser

side B.

2. Press button.

The corresponding LED "A/B" on the VAPORIX-Control unit must now flash
orange instead of green. The alarm is triggered, and the 72-hour time limit
begins to run.

3. Press button again.

The LED on the VAPORIX-Control unit must now flash red instead of orange
and the fuel discharge of the dispenser concerned (side A or B) must be
blocked.

4. Turn coding switch to "5" for dispenser side A or to "6" for dispenser side B

in order to release the dispenser point.

5. To log out, turn coding switch to "9" and press button (yellow LED goes out).

If the test shutdown is not cancelled by the service personnel within
a period of 10 minutes, an automatic reset of the test shutdown is
performed by the VAPORIX-Control measurement analysis unit.

4.4

Releasing a dispenser point that is shut down, for testing
If a dispenser point has been automatically shut down due to a system error, it
can be temporarily released for service purposes (e.g. control measurements).

1. Turn coding switch to "3" for dispenser side A or to "4" for dispenser side B.

2. Press button.

The dispenser point is released until the dongle is logged out again.

3. To log out, turn coding switch to "9" and press button (yellow LED goes out)

or perform further service activities.

After 60 minutes, a release of the dispenser point for testing and
servicing purposes is reset by the VAPORIX-Control measurement
analysis unit, provided that a reset operation has not already been
performed by service personnel.

Summary of Contents for VAPORIX

Page 1: ...VAPORIX VAPORIX Service Dongle and VAPORIX Diagnostics Art No 207082 Edition 2016 08 Version 3 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany Phone 49 0 40 39 82 07 0 Fax 49 0 40 390 63 39...

Page 2: ...gle 3 1 Characteristic features of the VAPORIX service dongle 3 2 Safety instructions 4 3 Structure and function 5 4 Connection and operation 7 5 Technical data 11 6 Overview coding switch commands 11...

Page 3: ...is needed to carry out service work on the automatic monitoring system VAPORIX which measures checks and evaluates vapour recovery at the fuel dispensers of filling stations The VAPORIX service dongl...

Page 4: ...ay only be carried out by expert personnel Specialized knowledge must be obtained by undergoing regular training Operators installers and service personnel must observe all applicable safety regulatio...

Page 5: ...not possible to e g alter the configuration of the VAPORIX system without authorisation The power supply of the service dongle is guaranteed by the measurement analysis unit VAPORIX Control After conn...

Page 6: ...l work carried out on the VAPORIX system which is only possible with the help of the service dongle is registered stored in the system and can be called up again using for example the optional signal...

Page 7: ...le during a fuel transfer 4 1 Connecting the service dongle to VAPORIX Control For the electrical connection of the service dongle the connecting cable s plug 8 must only be connected to the VAPORIX C...

Page 8: ...VAPORIX Control can be checked and registered the dongle must be logged in before operation 1 Turn coding switch to 0 2 Press button The yellow LED lights up as long as the communication to VAPORIX Co...

Page 9: ...ding switch to 9 and press button yellow LED goes out If the test shutdown is not cancelled by the service personnel within a period of 10 minutes an automatic reset of the test shutdown is performed...

Page 10: ...yellow LED goes out or perform further service activities 4 6 Checking the vapour recovery system To ensure that hydrocarbons are no longer present during a dry calibration of the vapour recovery sys...

Page 11: ...ket 25 pole to PC Pin 2 RxD Pin 3 TxD Pin 7 GND allfurtherpins notassigned SUB D plug 25 pole to VAPORIX Control Pin 2 TxD Pin 3 RxD Pin 6 5 V supply max 20 mA Pin 7 GND allfurtherpins notassigned 6 O...

Page 12: ...lation A free serial interface or USB interface with serial adapter for connection to the VAPORIX Control measurement analysis unit 3 Installation Insert the VAPORIX diagnostics floppy disk or CD ROM...

Page 13: ...ich you must specify the COM port to be used to carry out communication with the VAPORIX Control measurement analysis unit Select the COM port that is connected to the VAPORIX Control measurement anal...

Page 14: ...read in and display already available history data in graphical form by pressing the button Open After communication with the measurement analysis unit has been established by pressing the button Sta...

Page 15: ...s then deleted with the exception of the last 96 data entries Reorganizationpreventsidenticaldatafrombeingreadoutrepeatedly Following the reorganization process communication to the VAPORIX Control me...

Page 16: ...tabular form and as a diagram on separate worksheets The bottom card file tabs show the dispenser side that is applicable for the data Each line in the Microsoft Excel table corresponds to an evaluat...

Page 17: ...on of the history data of dispenser side B Hardwareversion Softwareversion Impulsevalue Serialnumber VAPORIX Control Upper limit Lower limit Fuel transfer rate Vapourtemperature For an analysis of the...

Page 18: ...ther information regarding the filling station location is initially scanned and included in a separate table sheet Enter the appropriate data in the dialog window Fig 9 Afterwards store the history d...

Page 19: ...result of direct or indirect use of the software or the documentation Excluded on a unlimited basis is above all liability for damages resulting from lost profit operational interruptions loss of info...

Reviews: