5
Technical data
Dimensions:
80 x 55 x 20 [mm]
Weight
(without cable)
:
60 g
Operating temperature: -10
°
C to +50
°
C
Pin assignment:
SUB-D socket, 25-pole to PC
Pin 2:
RxD
Pin 3:
TxD
Pin 7:
GND
all further pins: not assigned
SUB-D plug, 25-pole to VAPORIX-Control
Pin 2:
TxD
Pin 3:
RxD
Pin 6:
+5 V supply, max. 20 mA
Pin 7:
GND
all further pins: not assigned
6
Overview – coding switch commands
Function
Switch position
Dispenser side A
Dispenser side B
Alarm test
1
2
Service release
3
4
Alarm reset
5
6
Simulation
7
measurement
Log in
0
Log out