Page 21/46
Installation
4.4.3
Adjustment dimension X for tanks according to DIN 6618
DIN 6618
see Tables 7 or 8
Abbildung 16: Tanks nach DIN 6618
a = Response height
b = distance between the tank bottom and the tank lid (hexagon nut seat)
c = auxiliary distance dimension (upper edge of tank shell up to hexagon nut seat)
h = max. filling height / response height (see tables 7-8)
x = Overfill Prevention Sensor adjustment dimension (see tables 7-8)
y = control dimension
(1)
Use value „a“ from table 8
(2)
Measuring the auxiliary distance c (upper edge of tank shell up to hexagon nut seat)
Calculate the adjustment dimension "x": x = a + c
(3)
If the determination of the adjustment dimension "x" is not possible by this proce-
dure, following method can also be used: Measure value „b“ by dipping (middle of the
tank) and use value „h“ from the table 7. Calculate the adjustment dimension "x":
x = b –h
x
y
h
b
a
c
Pr
ob
e l
en
gt
h