background image

 

Variable LPG Installation Kit  

Page 3/5 

(3)

 

Push the float (6) on the installation tube (5) and reinstall the adjusting ring (7) at 

the lower end of the installation tube. 

 

 

 

Make sure that the adjusting ring (7) is fixed. 

 

Make sure that the float (6) points with the TOP mark towards the flange (8). 

 

ELECTROSTATIC HAZARD: When using a plastic float in potentially explosive 
areas, it must be ensured during installation, operation and maintenance work 
that the float cannot ignite due to friction or electrostatic charge. 

(4)

 

Insert the installation tube  

in the tank opening and  

fix the flange onto the  

tank (red arrows). 

 
 
 
 
 
 
 
 

 

 

Make sure that the installation tube is still movable (white arrow). 

(5)

 

Carefully push down the installation tube until it touches the bottom of the tank. 
 

(7) 

(6) 

(5) 

(8) 

TANK 

Summary of Contents for 350094

Page 1: ...ical Documentation FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany T 49 40 39 82 07 0 Web www fafnir com Variable LPG Installation Kit Installation guide 350094 4 2023 10 Art No Version Edi...

Page 2: ...hortening the Installation Tube optional 4 3 3 Fixing the measuring sensor VISY Stick LPG 5 4 Offset settings with VISY Setup 5 Copyright Reproduction and translation are permitted solely with the wri...

Page 3: ...chable with NPT external thread for process connection and a reducer with a PTFE compression fitting detachable for fixing the measuring sensor VISY Stick LPG sensor see figure below Clamping ring PTF...

Page 4: ...ded in FAFNIR s scope of supply Pipe cutter for stainless steel if needed to shorten the installation tube not included in FAFNIR s scope of supply 3 Installation 3 1 Assembly of the Installation Tube...

Page 5: ...8 ELECTROSTATIC HAZARD When using a plastic float in potentially explosive areas it must be ensured during installation operation and maintenance work that the float cannot ignite due to friction or e...

Page 6: ...of the cutting ring fitting at the 2nd Marking hand tight first 9 Hold the fitting body and fix the cutting ring fitting with a 1 clockwise turn of the union nut After the fixing the cutting ring fit...

Page 7: ...d remove any dirt particles from the tube 4 Push the PTFE compression fitting 3 back on and fix the fitting body 3a with the union nut 3b to the installation tube 3 3 Fixing the measuring sensor VISY...

Page 8: ...FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany T 49 40 39 82 07 0 E mail info fafnir com Web www fafnir com...