Malfunctions
Direct intervention by the customer
In order to avoid unnecessary costs, ensure that the problem occurring in the machine is not included in the following table before calling the
servicing department.
DEFECT
The coffee machine does not function and
the indicator light (
2
) is off.
REMEDY
Check that the electricity is on.
Check the position of the main switch (
12
).
CAUSE
No electricity.
The coffee machine does not work but the
indicator light (
2
) is on.
Wrong programming of the switch-on times.Press the PROGR (
32
) key for a few sec-
onds to force switch-on.
Reprogram the clock (Paragraphs 3 and 4).
The coffee machine does not heat up.
Leak from edge of filter-holder (
21, 25
).Clean with the supplied brush.
The undercup gasket is dirty with coffee resi-
due.
Wrong position of the switch (
1a
).Press the switch knob (
1a
).
Coffee flow time too short.
Grind the coffee more finely.
Change the coffee
Coffee grinds too coarse.
Coffee too old.
Water leaks from under the machine.Clean the tank.
Drainage tank clogged.
The coffee is warm and weak (after normal
time of brew and flow).
Air bubble in thermosyphonic circulation sys-
tem.
Press the coffee distribution button 2/3 times
to try and eliminate the air bubble.
The reading on the pressure gauge (
8
) of the
pump pressure is greater than 9 bars.
The pumps by-pass valve is blocked.Call the authorized servicing department.