11. Programming measures
How to access the programming function
To enter the programming mode, press STOP/progr button
(
4
) and keep it pressed for a few seconds; the buzzer sounds
intermittently.
To exit the programming mode, after programming the various
drinks, press STOP/progr button (
4
) again.
Programming coffee measures
“Before programming the coffee dispensing push
EXWWRQV¿OOWKH¿OWHUKROGHUZLWKWKHFRUUHFWVHUYLQJ
of ground coffee. Don’t use coffee grouts for pro-
gramming servings.”
)LWDQGWLJKWHQWKH¿OWHUKROGHU
10
) on the coffee dispenser
unit, positioning the cup (or cups) under the nozzle (or nozzles)
RIWKH¿OWHUKROGHU
10
).
Press the coffee dispensing push button (
or
12
) cor-
responding to the required serving to be programmed.
When the amount of coffee in the cup reaches the required
level, press again the button to stop dispensing.
Repeat the above operations for the other coffee push but-
tons.
Note: if you make a programming mistake, use a new dose of
ground coffee and repeat the operation.
Programming
To perform the programming of the coffee dose follow the
procedure herebelow:
1)Place a container by the hot water distribution nozzle (
8
).
.HHSWKHGLVWULEXWRUNH\
9
).
3) When the quantity of water in the container has reached
the desired level, press again the key (
9
).
12. Water level control of boiler
7KHPDFKLQHLV¿WWHGZLWKDVHULHVRIDXWRPDWLFOHYHOFRQWURO
devices to keep the water in the boiler at a pre-set level.
Filling the boiler with water using the manual service
tap
This function should be used only if the electronic level control
devices are not working correctly.
3UHVVWKH¿OOLQJOHYHU
5
), taking care not to exceed the MAX.
level on the boiler water level indicator (
13
).
4
11
12
2
3
9
8
10
13
5
28
English