background image

9

Drwg. No.

4333

1

2

Button switch:

3

4

5

6

Photocells and Safety Edge:

12 13

PHOTOCELLS AND
SAFETY EDGE

24V OUTPUT (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)

Push Button Switch Pulin 3:

26

27

28

3

COMMON

Led to indicate status
of Open - Stop - Close
switches

RS RS

Connect a 12VAC
Relay (T4 Trimmer
Time from 2s to 255s)
to operate a 230V
lamp

Electric lock:

RS RS

Set the T4 Trimmer Time
to the lowest value The
electric lock is excited
for 2 seconds

7

3

LOW VOLTAGE ELECTRICAL CONNECTIONS

1

DIP-SWITCH 1:

ON: Photocells stop gate while opening,
       reverse it on closing once obstacle is
       removed

OFF: Photocells do not stop gate while
        opening, reverse it on closing in
        case of an obstacle

STOP

COMMON

OPEN

CLOSE

Limit switch:

10

COMMON

8

9

LIMIT SWITCH

CLOSE

LIMIT SWITCH

OPEN

Radio Contact:

COMMON

RADIO

CONT

ACT

- Open/Close (Standard)
- Travel reversing on
  pulsing
- Step by step

2

5

ON: Step by step. Stop in between

OFF: Standard operating mode

ON: Gate is not reversed while opening

OFF: Any pulse reverses the gate

DIP-SWITCH 2 and 5 (NEVER set BOTH of
them to ON at the same time):

Light

 

ON

 = Open gate

Light

 

OFF

 = Closed gate

Flashing 

(fast) 0.5s

 

= Closing gate

Flashing 

(normally) 1s 

= Opening gate

Flashing 

(slowly) 2s

 

= gate is stopped

24V 3W Indication Light:

3

11

Courtesy light:

Flashing lamp:

19 20

 230V MAX 25W

4

Power supply:

Single- and Three-
phase Motors:

ELECTRIC POWER CONNECTIONS

-

+

T1

MOTOR RUN TIME

OPEN / CLOSE
from 5 to 128s

T2

-

+

DWELL TIME

from 5 to 128s

7

230V

400V

CAPACITOR

18

16

17

COMMON

M

MOTOR

U

W

V

230V 50Hz SINGLE-

PHASE

21

22

NEUTRAL

S

LIVE

23

22

DIP-SWITCH 4 and 7:

21

22

T

R

S

LIVE

23

22

ON: Pre-flashing

OFF: No pre-flashing

ON: Lamp is not operating during
       Dwell Time. Automatic Mode.
OFF: It flashes during Dwell Time.
        Automatic Mode.

400V 50Hz THREE-

PHASE

Hold on switched (Deadman) control:

Pedestrian Opening:

Trimmer T3

-

+

OPERATING MODES

from 3 to 30s. It can be activated by

any pulse (eg. by remote control)

superior to 2s

3

DIP-SWITCH 3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic
          closing by pulse

Automatic / Semiautomatic:

Automatic Operation:

 any pulse opens the gate, the gate stays

open as long as the Dwell time expires as set by T2 trimmer, then
it closes automatically, no pulsing is required.

Semi-automatic Operation:

 any pulse opens the gate that stays

open. A second pulse to Close is required for the gate to close.

Open and Close operations are achieved "by holding a
switch on" (no relay self-holding is involved) therefore a
phisical attendance is required to keep the gate opening
or closing until either the button or key is released.

Remote Controlled Operations Excluded
during Dwell Time on Automatic Mode:

3

ON= Automatic Closing

OFF= Closing by Pulse

5

ON: Step by step. Stop in between

OFF: Standard Operations

With this setting it is not possible to operate the gate by remote control during the dwell time on automatic mode.
DIP-SWITCH 2=ON, 3=ON and 5=ON

DIP-SWITCH 6

6

ON= Deadman Control. Dip-switch 4=OFF
         and Dip-switch 3=OFF

OFF= Standard Operations

How it works: Set the clock to the required time. On the pre-set time the gate is automatically opened and held open. Any further pulsing (even
by remote control) is not accepted by the system until the time pre-set by the clock has expired. On expiring and after the pre-set dwell time
the gate is closed automatically.
T3 trimmer on to zero, Dip-Switch 3=ON.

DIP-SWITCH No.3=ON Automatic Closing

Time clock:

3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic
          closing by pulse

4

3

COMMON

COMMON

OPEN

NO

-

+

Pedestrian Trimmer 

T3

set on to zero

2

ON: No reversing on opening

OFF: Travel reversing on any pulsing

Dwell Time

from 5 to 128s

T2

-

+

COMMON

OPEN

4

3

LIVE

LIVE

Summary of Contents for VIGILO 2250

Page 1: ...FITTING INSTRUCTIONS GB ...

Page 2: ...fter fixing the location enclosure fit the mechanism into it carry out the electrical connections and the system is ready to work Once a pulse is given either by keyswitch or remote control the post starts rising A reflecting sticker makes it well visible and an optional flashing lamp or traffic lights ensure clear indication of the post movements or status An electronic control panel fitted with ...

Page 3: ...an be easily lifted out using mechanical aid Pic 2 IMPORTANT make sure the electric cables are not damaged or accidentally removed from termination ENCLOSURE COVER PLATE HYDRAULIC MOTOR PUMP POST COVER EDGE PROTECTION RUBBER RING HOUSING CYLINDER AND PISTON ASSEMBLY CABLE OF THE OPEN LIMIT SWITCH LOWERED POST 10 METRE LENGTH ELECTRIC MOTOR CABLE 10 METRE LENGTH LIFTING EYE LIFTING MECHANISM RISING...

Page 4: ...ide of the enclosure to the tube centre line Pic 13 and 14 Front view View of the side where a hole is provided for a cable duct to be fitted A hole will be required in the road surface where Vigilo 2250 is to be located as indicated in Pic 5 Provision is made within the unit for the entry of a Ø 50 mm duct to the electronic control unit the cables are 10 m long Provide a soakaway by pouring shing...

Page 5: ...ch cables should be pulled through the duct a rope pull through previously inserted and the inner assembly gently lowered onto the location enclosure IMPORTANT Pull the electric motor and limit switch cables through the duct to the control unit Be careful not to damage or remove the cables from their termination Pic 7 Once satisfied that the guide tube assembly is properly fitted inside the locati...

Page 6: ...ld be connected as indicated in the diagram a 20μF capacitor in parallel with the two live terminals Control unit ELPRO 10 PLUS CEI Power supply 230V 50Hz Electric Motor Cable 20μF capacitor fitted inside Elpro 10 PLUS CEI Earth Limit switch cable Important Bridge the Common and Limit Switch Close terminals 8 and 9 Read the description of the electronic control unit Elpro 10 PLUS CEI on page 8 Pic...

Page 7: ... square section of 1 5 mm2 for a distance not superior to 50 m For longer distances use 2 mm2 wires To connect the photo cells key or button operated switches and other accessories 1 mm2 wires can be used ESSENTIAL COMPONENTS OF THE INSTALLATION 1 Miri 4 flashing lamp with incorporated aerial 2 Prit 19 keyswitch 3 Polo 44 photo cell projector 4 Jubi 433 receiver in weather proof casing 5 Elpro 10 ...

Page 8: ...p while opening 2 ON Radio No reversing while opening 3 ON Automatic closing 4 ON Preflashing activated 5 ON Radio Step by step Stop in between 6 ON Dead Man Control Dip 4 OFF and Dip 3 OFF 7 ON No lamp on during dwell time 8 OFF No function T S R PULIN 3 26 27 28 3 DIP SWITCH ON OFF 1 4 5 6 7 8 2 3 L2 L3 L4 L5 L6 L7 L8 L9 1 7 4 10 11 12 13 19 20 2 8 5 3 9 6 STOP COMMON OPEN CLOSE 230V 25W max FLA...

Page 9: ...Automatic Mode 400V 50Hz THREE PHASE Holdonswitched Deadman control Pedestrian Opening Trimmer T3 OPERATING MODES from 3 to 30s It can be activated by any pulse eg by remote control superior to 2s 3 DIP SWITCH 3 ON Automatic Closing OFF No Automatic Semi automatic closing by pulse Automatic Semiautomatic Automatic Operation any pulse opens the gate the gate stays open as long as the Dwell time exp...

Page 10: ...US CEI GREEN RED Mains Supply 230V 50Hz IMPORTANT For security reasons failure of the red light prevents even the green light from illuminating Interface for the electrical connections of the green red traffic lights Traffic lights Red Light 230V 25 60W Green Light 230V 25 60W Limit Switch Contact Access Blocked Red Light Illuminated Bollard VIGILO 2250 Common Limit Swith Open Lowered bollard Limi...

Page 11: ...rd to lower the bollard 4 and eventually re establish normal operation by rotating the spanner clockwise to the original position 5 To re establish normal operation first turn the spanner clockwise to lock the hydraulic circuit make sure that the system is supplied with voltage and pulse for the bollard to rise Release spanner 3 One turn anti clockwise to over ride 2 Locate the spanner in the over...

Page 12: ...of an ever increasing process of improvement The CE mark certifies that the operator conforms to the essential requirements of the European Directive art 10 EEC 73 23 in relation to the manufacturer s declaration for the supplied items in compliance with the body of the regulations ISO 9000 UNI EN 29000 Automation in conformity to EN 12453 EN 12445 safety standard Bollard flush with ground level F...

Reviews: