4
INSTALLATION OF THE LOCATING ENCLOSURE
410 mm
845 mm
410 mm
170 mm
675 mm
Ø 275 mm
205 mm
205 mm
PIC. 3
205
205
410
410
170
205
PIC. 4
1,0 m
230 mm
230 mm
870 mm
435 mm
870 mm
PIC. 5
435 mm
The foundation enclosure is the component that is designed to house the automation and it should be set into the ground so that the
top of it is at ground level.
IMPORTANT
: the upper square section of the foundation enclosure (where the motor pump unit is to be fitted) is not centered to the
lower tube where the guide tube and piston assembly are to be located: there is a distance of 17 cm from the "back side" of the enclosure
to the tube centre line (Pic. 13 and 14).
Front view
View of the side where a hole is
provided for a cable duct to be fitted
- A hole will be required in the road surface where Vigilo 2250 is to be located, as indicated in Pic. 5. Provision is made within the unit
for the entry of a Ø 50 mm duct to the electronic control unit (the cables are 10 m long). Provide a soakaway by pouring shingle into
the hole up to 15 cm from bottom level.
Front side
Back side
Depth to hole
centre 120 mm
FRONT SIDE
BACK SIDE
FRONT SIDE
BACK SIDE
15 cm
Shingle to provide
a soakaway
12 cm
Depth from duct centre.
This duct to lead the cables
to the control unit
Ø50 mm duct for the
cables to be connected
to the control panel
(cable length 10 metres)
Locating tube
Electronic
control unit
Elpro 10 PLUS CEI