Safety Switch
Radio Power Supply
1
2
24V Power supply
16 17
LOW VOLTAGE ELECTRICAL CONNECTIONS
Push Button
Switch:
Photocell:
18 19
PHOTOCELL
CONTACT
POWER SUPPLY 24V
LIGHT
+24V
16 17
Drwg. No.
4138
1
DIP-SWITCH 1:
ON: Photocells stop gate while opening,
reverse it on closing once obstacle is
removed
OFF: Photocells do not stop gate while
opening, reverse it on closing in
case of an obstacle
Limit switch:
15
COMM
ON
13 14
LIMIT SWITCH
CLOSE
LIMIT SWITCH
OPEN
Radio Contact:
10
9
COMMON
RADIO
CONT
ACT
- Open/Close (Standard)
- Travel reversing on pulsing
- Step by step
2
5
ON: Step by step. Stop in between
OFF: Standard operating mode
ON: Gate is not reversed while opening
OFF: Any pulse reverses the gate
DIP-SWITCH 2 and 5 (NEVER set BOTH of them to ON at the same time):
STOP
COMMON
OPEN
CLOSE
3
4
5
INDICATION
LAMP OPEN
48V max 3A
INDICATION
LAMP CLOSE
48V max 3A
7
8
6
24V 3W Indication Light:
Light
ON
= Open gate
Light
OFF
= Closed gate
Flashing
(fast) 0.5s
= Closing gate
Flashing
(normally) 1s
= Opening gate
Flashing
(slowly) 2s
= gate is stopped
Electric lock:
Set the T4 Trimmer Time to the lowest value
The electric lock is excited for 2 seconds
Connect a 12VAC Relay
(T4 Trimmer Time from 2s to 255s)
to operate a 230V lamp
Courtesy light:
SINGLE-/THREE-PHASE FOR SLIDING GATE OPERATORS MEC 200
PLUS
70/3