background image

Support
bracket

Door fully open

Door fully closed

M18 locking

nut

Hexagonal 
head x E13

Z20 x 1/2”

pinion

Chain tensioner

  Z20 x 1/2”

VIEW FROM WALL SIDE

CHAIN TENSIONER

The chain tensioner is to be fixed to the wall, or a bracket, by suitable bolts depending on the nature of the  wall itself, and the 
position  is to be the most appropriate to allow installation and the subsequent adjustment of chain tension (the hexagonal head 
to be on the side opposite the one facing MEC 200 LB).
• Loosen M18 nut to unlock the tensioner pinion.
• Adjust the position of the pinion as required by screwing or unscrewing the hexagonal head positioned on the side.
• Once satisfied the pinion is in the correct position for the chain to stay stretched, the M18 nut is to be locked back.

MOUNTING AND FASTENING MEC 200 LB

MEC  200  LB  is  to  be  mounted  by  positioning  and  fastening  the  motor  base  plate  on  to  the  previously  fixed  support  bracket.
With  the  door  in  fully  open  position  there  must  be  a  clearance  of  10-15  cm  as  indicated  in  the  picture,  with  reference  to  the 
pinion.

Pic. 5

Pic. 4

E

n

g

li

sh

5

!

!

10 - 15 cm

10 - 15 cm

MEC 200 LB

Chain-drive electromechanical operator 

for sectional, folding and industrial doors

GREASE

GREASE

Summary of Contents for MEC 200 LB

Page 1: ...EN 13241 EN 12453 EN 12445 MEC 200 LB Chain drive electromechanical operator for sectional folding and industrial doors 1 12 GB instructions manual pages the gate opener...

Page 2: ...he gate warning about the presence of an automated installation The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier including la...

Page 3: ...t is strong and reliable The torque control is by mechanical clutch system adjustable by hand Worm and gear coupling made of steel and bronze mounted on bearings all parts in an oil bath The manual re...

Page 4: ...7 Fit 55 photocell receiver 8 Cable release lever optional 9 MEC 200 LB 10 Miri 4 flasher with incorporated aerial 11 Elpro 37 electronic control box and VIX 53 2 R plug in radio receiver card 12 230...

Page 5: ...unlock the tensioner pinion Adjust the position of the pinion as required by screwing or unscrewing the hexagonal head positioned on the side Once satisfied the pinion is in the correct position for t...

Page 6: ...ble by metallic cable whose device can be positioned within easy reach on the wall optional on request or by a lever with a ring at the end to be pulled by a hook not included in the equipment English...

Page 7: ...manual release move the contact shaft halfway the travel manually move the door to the closed position on to the door stop or very close to it by a screwdriver onto the dedicated adjusting screw drive...

Page 8: ...ternal limit switches recommended for doors wider than 8 meters does not require any adjustment the open and close limit switches are to be positioned in a way they correspond to the actual open and c...

Page 9: ...No 2036L 3 1 2 chain item code No 2054L 4 Fixing plate item code No 2046L 5 MEC 200 LB item code No 2051L 6 Cable release item code No 2044L 7 Lateral running tracks 8 Sectional door APPLICATION OF M...

Page 10: ...ystem cover Fastening of the left door Fastening of the right door Electric lock mounted on post Door to move this way to close Electric lock mounted on a post Lock catcher fixed on to the door VIEW F...

Page 11: ...barrier Operator model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary s...

Page 12: ...speed Capacitor Intermittent service Single phase 0 37 kW 0 5 HP 230 Vac 510 W 2 4 A 20 F Three phase 0 37 kW 0 5 CV 230 400 Vac 575 W 2 1 1 2 A Single phase 0 73 kW 1 0 CV 230 Vac 50 Hz 1 130 W 5 7...

Reviews: