WIRING DIAGRAM AND LAYOUT OF THE ACCESSORIES
Before installing MEC 200 LB it is advisable that the preparatory works be made for all of the accessories required at least to
ensure safety and proper control of the system.
1 - Chain tensioner
2 - External limit switch for MEC 200 LB version without incorporated limit switches (optional not included)
3 - Chis 37 keyswitch
4 - Fit 55 photocell transmitter
5 - Ground door stop
6 - VIX 53 radio transmitter
7 - Fit 55 photocell receiver
8 - Cable release lever (optional)
9 - MEC 200 LB
10 -
Miri 4 flasher with incorporated aerial
11 - Elpro 37 electronic control box and VIX 53/2 R plug-in radio receiver card
12 - 230 V - 50 Hz - 0,03 A magneto-thermal circuit breaker (recommended cable section 2,5 mm² beyond 100 m )
230 V - 50 Hz
±10%
Pic. 3
General indicative layout: it is the installer’s care and responsibility to properly lay the tubes required for the electrical connections.
En
g
lis
h
2
2
3
4
1
8
11
10
4
12
4x1 mm²
4x1 mm²
2x1 mm²
2x1 mm²
2x1 mm²
3x1 mm²
5
5
6
2x1 mm²
RG58
7
9
MEC 200 LB
Chain-drive electromechanical operator
for sectional, folding and industrial doors