General layout for guidance:  it is the installer’s responsibility to lay the conduits for the electrical connections in a proper and correct 
way.

electro-mechanical geared motor

with chain-drive system for heavy industrial sliding gates

GENERAL LAYOUT OF THE INSTALLATION

For installations where large gates are involved, pre-existing accessories can be found, speci cally dedicated to the type of gate 
to be operated. Therefore the installation diagram of the components as represented below is to be considered only indicative, 
and cannot be limited to the accessories here included.

Supply voltage

230 V - 50/60 Hz

NOTE WELL: the entire electrical equipment is to be properly connected to ground.

 

 1 - 230 V - 50/60 Hz, 0,03 A, magneto-thermal differential circuit breaker (not included)

  2 - Control board with power contactors and plug-in radio receiver card
  3 - Three-phase FIBO 300 LB or FIBO 400 LB geared motor
  4 - Flasher 
  5 - Opening external limit switch 
  6 - Closing external limit switch
  7 - Photocell transmitter
  8 - Photocell receiver
  9 - Key-switch
10 - Transmitter

Pic. 5

Types of cables to be used:

 

For power supply to motors, safety and command accessories: FROR CEI 20-20 CEI EN 50267-2-1
For the aerial: RG58 (included, 3 m)
NOTE: for distances beyond 50 m increase the cable square section to suit the real absorption requirements of the 
devices as indicated in the CEI EN 60204-1 norms.

Summary of Contents for FIBO 300 LB-1,5 HP

Page 1: ...300 LB 1 5 HP FIBO 400 LB 3 0 HP Electro mechanical geared motor for heavy industrial sliding gates Worm crown gear inner coupling in an oil bath entirely supported by ball bearings Chain drive Three...

Page 2: ...DECLARATION OF CONFORMITY of the manufacturer Meccanica Fadini snc Via Mantova 177 A 37053 Cerea VR Italy declares under own responsibility that Fibo 300 LB Fibo 400 LB comply with the 2006 42 CE Mac...

Page 3: ...ors for heavy sliding gates driven bya chain it is available in 1 1 kW 1 5 HPthree phase and 2 2 kW 3 0 HP three phase versions FIBO 300 LB FIBO 400 LB are a versatile motor powered units and can suit...

Page 4: ...nd chain the number of teeth and pitch can change OVERRIDE FOR MANUAL OPERATION In order to disconnect the gate from the FIBO 300 LB FIBO 400 LB geared motors in situations where power failure is occu...

Page 5: ...ccessories here included Supply voltage 230 V 50 60 Hz NOTE WELL the entire electrical equipment is to be properly connected to ground 1 230 V 50 60 Hz 0 03 A magneto thermal di erential circuit break...

Page 6: ...Fibo 400 LB MOTOR CONNECTIONS Pic 6 Motor terminal board Elpro 37 HP with power contactors 400 V Three phase connections electro mechanical geared motor with chain drive system for heavy industrial s...

Page 7: ...60 Hz 11 m 1 Hydraulic oil type Oil Fadini art 706L Working temperature 25 C 80 C Fibo 300 LB weight 28 kg Protection standard IP 55 PERFORMANCE Service cycle 25 s opening 30 s dwell 25 s closing 30...

Page 8: ...PERFORMANCE Service cycle 25 s opening 30 s dwell 25 s closing 30 s dwell Complete cycle time 110 s Complete opening dwell closing dwell cycles No 33 hour Annual cycles with 8 hours of use per day No...

Reviews: