background image

Fibo 300 LB

Fibo 400 LB

2

electro-mechanical geared motor

with chain-drive system for heavy industrial sliding gates

GENERAL WARNINGS FOR PEOPLE SAFETY

THANK YOU

Thank you for purchasing a Fadini product. 

Please  read  these  instructions  carefully  before  using  this 

appliance.  The  instructions  contain  important  information 

which  will  help  you  get  the  best  out  of  the  appliance  and 

ensure safe and proper installation, use and maintenance. Keep 

this manual in a convenient place so that you can always refer 

to it for the safe and proper use of the appliance.

INTRODUCTION 

This operator is designed for a speci c scope of applications as 

indicated in this manual, including safety, control and signaling 

accessories as minimum required with 

Fadini

 equipment. 

 Any 

applications not explicitly included in this manual may cause 

operation  problems  or  damages  to  properties  and  people. 

 

Meccanica Fadini snc is not liable for damages caused by the 

incorrect use of the equipment, or for applications not included 

in this manual or for malfunctioning resulting from the use of 

materials  or  accessories  not  recommended  by  the 

manufacturer. 

 The manufacturer reserves the right to make 

changes to its products without prior notice. 

 All that is not 

explicitly  indicated  in  this  manual  is  to  be  considered  not 

allowed.

BEFORE INSTALLATION

Before commencing operator installation assess the suitability 

of the access, its general condition and the structure. 

 Make 

sure  that  there  is  no  risk  of  impact,  crushing,  shearing, 

conveying,  cutting,  entangling  and  lifting  situations,  which 

may prejudice people safety. 

 Do not install near any source of 

heat and avoid contacts with  ammable substances. 

 Keep all 

the  accessories  able  to  turn  on  the  operator  (transmitters, 

proximity  readers,  key-switches,  etc)  out  of  the  reach  of  the 

children. 

  Transit  through  the  access  only  with  stationary 

operator. 

 Do not allow children and/or people to stand in the 

proximity  of  a  working  operator. 

  To  ensure  safety  in  the 

whole  movement  area  of  a  gate  it  is  advisable  to  install 

photocells,  sensitive  edges,  magnetic  loops  and  detectors. 

 

Use yellow-black strips or proper signals to identify dangerous 

spots. 

  Before  cleaning  and  maintenance  operations, 

disconnect the appliance from the mains by switching off the 

master  switch. 

  If  removing  the  actuator,  do  not  cut  the 

electric wires, but disconnect them from the terminal box by 

loosening the screws inside the junction box.

INSTALLATION

All  installation  operations  must  be  performed  by  a  quali ed 

technician,  in  observance  of  the  Machinery  Directive 

2006/42/CE  and  safety  regulations  EN  12453  -  EN  12445. 

Verify the presence of a thermal-magnetic circuit breaker 0,03 

A  -  230  V  -  50/60  Hz  upstream  the  installation. 

  Use 

appropriate  objects  to  test  the  correct  functionality  of  the 

safety  accessories,  such  as  photocells,  sensitive  edges,  etc. 

□ 

 

Carry out a risk analysis by means of appropriate instruments 

measuring the crushing and impact force of the main opening 

and closing edge in compliance with EN 12445. 

 Identify the 

appropriate solution necessary to eliminate and reduce such

risks. 

Meccanica Fadini s.n.c.

Director in charge

CE DECLARATION OF CONFORMITY of the manufacturer:

Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under own responsibility that: 

Fibo 300 LB - 

Fibo 400 LB

 comply with the 2006/42/CE Machinery Directive, and also that they are sold to be installed in an “automatic 

system”, along with original accessories and components as indicated by the manufacturing company. An automatic gate 

operator is, by law, a “machinery” and therefore the installer must  t the equipment with all of the applicable safety norms. 

The installer is also required to issue the installer’s Declaration of Conformity. The manufacturer is not liable for possible 

incorrect use of the product. The product complies with the following speci c norms: analysis of the risks and subsequent 

action to cure them as per EN 12445 and EN 12453, Low Voltage Directive 2014/35/UE, Electromagnetic Compatibility 

2014/30/UE. In order to certify the product, the manufacturer declares under own responsibility the compliance with the 

EN 13241-1 PRODUCT NORMS.

 

In  case  where  the  gate  to  automate  is  equipped  with  a 

pedestrian entrance, it is appropriate to prepare the system in 

such a way to prohibit the operation of the engine when the 

pedestrian entrance is used. 

 Apply safety nameplates with 

CE  marking  on  the  gate  warning  about  the  presence  of  an 

automated  installation. 

  The  installer  must  inform  and 

instruct the end user about the proper use of the system by 

releasing  him  a  technical  dossier,  including:  layout  and 

components  of  the  installation,  risk  analysis,  veri cation  of 

safety accessories, veri cation of impact forces and reporting 

of residual risks.

INFORMATION FOR END-USERS

The  end-user  is  required  to  read  carefully  and  to  receive 

information concerning only the operation of the installation 

so that he becomes himself responsible for the correct use of it. 

 The end-user shall establish a written maintenance contract 

with  the  installer/maintenance  technician  (on  -call). 

  Any 

maintenance operation must be done by quali ed technicians. 

 Keep these instructions carefully.

WARNINGS FOR THE CORRECT OPERATION OF THE 

INSTALLATION

 

For  optimum  performance  of system over  time according  to 

safety  regulations,  it  is  necessary  to  perform  proper 

maintenance  and  monitoring  of  the  entire  installation:  the 

automation,  the  electronic  equipment  and  the  cables 

connected to these. 

 The entire installation must be carried 

out by quali ed technical personnel,  lling in the Maintenance 

Manual  indicated  in  the  Safety  Regulation  Book  (to  be 

requested 

or 

downloaded 

from 

the 

site 

www.fadini.net/supporto/downloads). 

 

Operator: 

maintenance inspection at least every 6 months, while for the 

electronic equipment and safety systems an inspection at least 

once every month is required. 

 The manufacturer, Meccanica 

Fadini  snc,  is  not  responsible  for  non-observance  of  good 

installation  practice  and  incorrect  maintenance  of  the 

installation.

DISPOSAL OF MATERIALS

Dispose  properly  of  the  packaging  materials  such  as 

cardboard,  nylon,  polystyrene  etc.  through  specializing 

companies (after veri cation of the regulations in force at the 

place of installation in the  eld of waste disposal). Disposal of 

electrical  and  electronic  materials:  to  remove  and  dispose 

through specializing companies, as per Directive 2012/19/UE. 

Disposal of substances hazardous for the environment is

prohibited.

Summary of Contents for FIBO 300 LB-1,5 HP

Page 1: ...300 LB 1 5 HP FIBO 400 LB 3 0 HP Electro mechanical geared motor for heavy industrial sliding gates Worm crown gear inner coupling in an oil bath entirely supported by ball bearings Chain drive Three...

Page 2: ...DECLARATION OF CONFORMITY of the manufacturer Meccanica Fadini snc Via Mantova 177 A 37053 Cerea VR Italy declares under own responsibility that Fibo 300 LB Fibo 400 LB comply with the 2006 42 CE Mac...

Page 3: ...ors for heavy sliding gates driven bya chain it is available in 1 1 kW 1 5 HPthree phase and 2 2 kW 3 0 HP three phase versions FIBO 300 LB FIBO 400 LB are a versatile motor powered units and can suit...

Page 4: ...nd chain the number of teeth and pitch can change OVERRIDE FOR MANUAL OPERATION In order to disconnect the gate from the FIBO 300 LB FIBO 400 LB geared motors in situations where power failure is occu...

Page 5: ...ccessories here included Supply voltage 230 V 50 60 Hz NOTE WELL the entire electrical equipment is to be properly connected to ground 1 230 V 50 60 Hz 0 03 A magneto thermal di erential circuit break...

Page 6: ...Fibo 400 LB MOTOR CONNECTIONS Pic 6 Motor terminal board Elpro 37 HP with power contactors 400 V Three phase connections electro mechanical geared motor with chain drive system for heavy industrial s...

Page 7: ...60 Hz 11 m 1 Hydraulic oil type Oil Fadini art 706L Working temperature 25 C 80 C Fibo 300 LB weight 28 kg Protection standard IP 55 PERFORMANCE Service cycle 25 s opening 30 s dwell 25 s closing 30...

Page 8: ...PERFORMANCE Service cycle 25 s opening 30 s dwell 25 s closing 30 s dwell Complete cycle time 110 s Complete opening dwell closing dwell cycles No 33 hour Annual cycles with 8 hours of use per day No...

Reviews: