background image

7

4138

Drwg. No.

GB

SINGLE-/THREE-PHASE FOR SLIDING GATE OPERATORS MEC 200

PLUS

70/3

®

22 23

 230V MAX 25W

230V

400V

Dwell Time

from 5 to 128s

T2

-

+

-

+

-

+

27

22

R

T

S

LIVE

29

28

230V 

±

10% 50Hz

SINGLE-PHASE

NEUTRAL

LIVE

400V 

±

10% 50Hz THREE-PHASE

 230/400V 

±

10% 50Hz

THREE-PHASE MOTOR

M

U

W

V

25

26

24

230V 

±

10% 50Hz

SINGLE-PHASE

MOTOR

M

U

W

V

25

26

24

 16

µ

F CAPACITOR

Led Status Indication:
L1 = 230V 50Hz power supply. Alight
L2 = Photocells, if obstructed light goes off
L3 = Open. Alight whenever an Open pulse is given
L4 = Close. Alight whenever a Close pulse is given
L5 = Stop. It goes off on pulsing Stop
L6 = Radio. It goes on by pressing a transmitter button
L7 = Gate Status; it flashes on gate moving
L8 = Limit switch Close; off when gate is closed
L9 = Limit switch Open; off when gate is open
L10 = It stays on for a time equal to the time set on T4 Trimmer

Single- (230V) and
Three-phase (400V) Motors:

T1 MOTOR RUN TIME

OPEN / CLOSE
from 5 to 150s

Flashing lamp:

4

7

DIP-SWITCH 4 and 7:

ON: Pre-flashing

OFF: No pre-flashing

ON: Lamp is not operating during

Dwell Time. Automatic Mode.

OFF: It flashes during Dwell Time .

Automatic Mode.

Power supply:

FADINI

l'apricancello

T2 DWELL TIME

from 5 to 150s

Hold on switched (Deadman) control:

DIP-SWITCH 6

6

ON= Deadman Control. Dip-switch 4=OFF

and Dip-switch 3=OFF

OFF= Standard Operations

3

DIP-SWITCH 3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic
          closing by pulse

Automatic / Semiautomatic:

Pedestrian Opening:

Trimmer T3 from 3 to 30s.
It can be activated by any pulse (eg. by remote control) superior to 2s

COMMON

ELECTRICAL POWER CONNECTIONS

OPERATING MODES

-

+

Trimmer

T3